Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

1.60315

Supelco

Sulfuric acid solution

c(H₂SO₄), 5 M (10 N), ready-to-use volumetric solution for titration, Titriplex®

Sinónimos:

Sulfuric acid solution

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
H2SO4
Número de CAS:
Peso molecular:
98.08
Beilstein/REAXYS Number:
2037554
MDL number:
UNSPSC Code:
12352322
NACRES:
NA.21

product name

Sulfuric acid, 5 M H2SO4 (10 N), Titripur®

product line

Titripur®

Quality Level

form

liquid

quality

Analyzed in our ISO 17025 accredited QC lab

reaction suitability

reaction type: Acid-base reactions

concentration

5 M H2SO4 (10 N)

technique(s)

titration: suitable

storage temp.

15-25°C

SMILES string

OS(O)(=O)=O

InChI

1S/H2O4S/c1-5(2,3)4/h(H2,1,2,3,4)

InChI key

QAOWNCQODCNURD-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Application


  • Uranium capture from aqueous solution using palm-waste based activated carbon: sorption kinetics and equilibrium.: This study uses sulfuric acid in the activation process of palm-waste carbon for uranium capture, highlighting its effectiveness in water treatment applications (Youssef et al., 2024).

  • Ion chromatography for the determination of n-butylamine in the workplace air.: Utilizes sulfuric acid in ion chromatography to determine n-butylamine levels in workplace air, crucial for occupational safety and health monitoring (Chen et al., 2024).

  • Effect of Sulfuric Acid Corrosion on Flotation Performance of Calcite by Changing Surface Roughness.: Explores how sulfuric acid-induced corrosion affects the flotation performance of calcite by altering its surface roughness, important for mineral processing industries (Xing et al., 2024).

  • An active derivatization detection method for inline monitoring the isolation of carbohydrates by preparative liquid chromatography.: This research presents a novel method using sulfuric acid for inline monitoring and derivatization in carbohydrate isolation, enhancing preparative liquid chromatography techniques (Yao et al., 2024).

  • Extraction and Fractionation of Human Gastric Mucins from Gastric Juice.: Demonstrates the use of sulfuric acid in the extraction and fractionation of human gastric mucins, contributing to gastrointestinal research and diagnostics (Kawashima et al., 2024).

Features and Benefits

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Analysis Note

Form liquid
Amount-of-substance concentration 4.975 - 5.025 mol/L
Measurement uncertainty ± 0.015 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Legal Information

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Referencia del producto
Descripción
Precios

pictograms

Corrosion

signalword

Danger

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Storage Class

8B - Non-combustible, corrosive hazardous materials

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico