Saltar al contenido
Merck

109576

Sigma-Aldrich

1,1′-Dimethylferrocene

95%

Sinónimos:

Bis(methylcyclopentadienyl)iron

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C12H14Fe
Número de CAS:
Peso molecular:
214.08
EC Number:
MDL number:
UNSPSC Code:
12161600
PubChem Substance ID:
NACRES:
NA.22

assay

95%

form

solid

reaction suitability

core: iron
reagent type: catalyst

mp

37-40 °C (lit.)

SMILES string

[Fe].C[C]1[CH][CH][CH][CH]1.C[C]2[CH][CH][CH][CH]2

InChI

1S/2C6H7.Fe/c2*1-6-4-2-3-5-6;/h2*2-5H,1H3;

InChI key

GJFIEPAJMYPAGC-UHFFFAOYSA-N

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

226.4 °F - closed cup

flash_point_c

108.00 °C - closed cup

ppe

Eyeshields, Gloves, type N95 (US)


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

K B Male et al.
Applied biochemistry and biotechnology, 61(3), 267-276 (1996-12-01)
1,1'-dimethylferricinium (DMFe+), a stable and pH-insensitive blue dye, was prepared via enzymatic oxidation of a 1,1'dimethyl-ferrocene (DMFe):2-hydroxypropyl-beta-cyclodextrin (HPCD) water-soluble inclusion complex, using bilirubin oxidase immobilized onto porous aminopropyl glass beads via glutaraldehyde activation. In the presence of glucose, DMFe+ was
J C Pickup et al.
Biosensors, 4(2), 109-119 (1989-01-01)
The major problems with existing amperometric enzyme electrodes for glucose sensing are oxygen sensitivity and output drift. The recently described miniature glucose sensors using immobilised ferrocene (dicyclopentadienyl iron) to mediate electron transfer from glucose oxidase to a base electrode are
J C Pickup et al.
Biosensors, 3(6), 335-346 (1987-01-01)
The special requirements for implantable glucose sensors which differ from laboratory analysers and in vitro probes include continuous operation without drift, compatibility with in vivo body conditions, electrical and toxicological safety and patient acceptability. We have studied the effect of
Y Liu et al.
Applied biochemistry and biotechnology, 62(2-3), 105-117 (1997-02-01)
The structure and properties of the blend of regenerated silk fibroin (RSF) and poly(vinyl alcohol) (PVA) were investigated. The two polymers in the blend are in the state of phase segregation. Infrared (IR) spectra indicate that the RSF in the
A Alexandre et al.
Biochemical and biophysical research communications, 139(2), 509-514 (1986-09-14)
The synthetic antioxidants butylated hydroxytoluene (BHT), nordihydroguaiaretic acid and the one-electron donor 1,1'-dimethylferrocene, inhibit cytosolic Ca++ increase, shape change, aggregation and ATP secretion in aspirinated washed human platelets stimulated by thrombin, vasopressin and platelet-activating factor. The antioxidants also inhibit cytosolic

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico