While most HPLC columns feature 10.32 threaded end fittings, some may have different types and sizes of fittings. Given the wide variety of HPLC systems, it is not possible to guarantee with complete certainty that a specific HPLC system utilizes 10.32 fittings. Furthermore, even within a single type of fitting, such as 10.32, there are short, standard, and extended versions of the nut and ferrule. Hence, it is advisable to consult the instrument manual to determine the correct fitting type and size.
1.50247
Purospher® STAR NH2 (5 µm) HPLC Columns
L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
Synonym(s):
Purospher® STAR NH2 (5 µm) LiChroCART™ 150-4.6
About This Item
Recommended Products
Product Name
Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
material
stainless steel column
Quality Level
Agency
suitable for USP L8
product line
Purospher®
feature
endcapped: no
packaging
1 ea of
extent of labeling
3.5% Carbon loading
parameter
250 bar pressure
60 °C max. temp.
technique(s)
HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (Low - Medium)
column L × I.D.
15 cm × 4.6 mm
surface area
330 m2/g
matrix
fully porous particle
matrix active group
NH2 bonding phase
particle size
5 μm
pore size
120 Å pore size
operating pH range
2-7.5
separation technique
hydrophilic interaction (HILIC)
normal phase
reversed phase
storage temp.
no temp limit
Related Categories
General description
Application
Features and Benefits
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
Analysis Note
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
Is the product Purospher® STAR NH2 (5 µm) LiChroCART® 150-4.6 column (catalog number 1.50247.0001 or 48219-474) compatible with the Agilent 1260 HPLC system?
1 answer-
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service