Skip to Content
Merck
All Photos(1)

Key Documents

1.70333

Supelco

Mercury ICP standard

traceable to SRM from NIST Hg(NO₃)₂ in HNO₃ 10% 1000 mg/l Hg Certipur®

Synonym(s):

Mercury Calibration Standard for ICP

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41116107
NACRES:
NA.24

grade

certified reference material

Quality Level

Agency

suitable for EPA 200.7
suitable for EPA 200.8

product line

Certipur®

technique(s)

ICP: suitable

density

1.054 g/cm3 at 20 °C

application(s)

industrial qc
pharmaceutical

format

single component solution

storage temp.

15-25°C

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.

Application


  • Mercury ICP standard for trace metal analysis: A study utilizes ICP-MS to assess comparability and uncertainty in analytical methods for methylated mercury species in seawater, demonstrating the critical role of mercury ICP standards in environmental monitoring and trace metal analysis (Anal Chim Acta, 2023; doi: 10.1016/j.aca.2023.341735).

  • High-purity mercury calibration standard for ICP-MS: Research highlights a broad-applicability method for mercury speciation in various seafoods using ICP-MS, emphasizing the necessity of high-purity mercury standards for accurate and reliable trace metal quantification (Anal Methods, 2023; doi: 10.1039/d3ay00289f).

  • Mercury standard for pharmaceutical impurity testing: An innovative application discussed involves the comparative toxicity of interferon beta-1a impurities, including heavy metal ions, underscoring the importance of mercury ICP standards in pharmaceutical quality control to ensure safety and compliance (Medicina, 2022; doi: 10.3390/medicina58040463).

  • Traceable mercury ICP standard for biochemistry research: A study on the quantitative mapping of mercury in mushroom fruit bodies using ICP-MS validates the need for traceable mercury standards in biochemistry research, facilitating detailed elemental distribution analyses (Anal Bioanal Chem, 2022; doi: 10.1007/s00216-022-04240-y).

  • Mercury reference material for biotech quality control: Research integrating smartphone-based electrochemical analysis with NFC systems for the detection of heavy metals showcases the utility of mercury ICP standards as reference materials in developing portable, high-tech solutions for biotech applications (Mikrochim Acta, 2022; doi: 10.1007/s00604-022-05281-x).

Other Notes

Blocked in the US and Canada due to regulatory reasons
For a complete product listing of our Certipur® range of CRMs for ICP and AAS, technical information, and example certificates please visit our ICP & AAS standards website

Legal Information

CERTIPUR is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Health hazardCorrosion

Signal Word

Danger

Hazard Statements

Hazard Classifications

Aquatic Chronic 3 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - STOT RE 2

Target Organs

Kidney

Supplementary Hazards

Storage Class Code

6.1B - Non-combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 2

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.

A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.

A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.

A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.

Related Content

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service