Accéder au contenu
Merck

A 3D-printed device for a smartphone-based chemiluminescence biosensor for lactate in oral fluid and sweat.

The Analyst (2014-10-25)
Aldo Roda, Massimo Guardigli, Donato Calabria, Maria Maddalena Calabretta, Luca Cevenini, Elisa Michelini
RÉSUMÉ

Increasingly, smartphones are used as portable personal computers, revolutionizing communication styles and entire lifestyles. Using 3D-printing technology we have made a disposable minicartridge that can be easily prototyped to turn any kind of smartphone or tablet into a portable luminometer to detect chemiluminescence derived from enzyme-coupled reactions. As proof-of-principle, lactate oxidase was coupled with horseradish peroxidase for lactate determination in oral fluid and sweat. Lactate can be quantified in less than five minutes with detection limits of 0.5 mmol L(-1) (corresponding to 4.5 mg dL(-1)) and 0.1 mmol L(-1) (corresponding to 0.9 mg dL(-1)) in oral fluid and sweat, respectively. A smartphone-based device shows adequate analytical performance to offer a cost-effective alternative for non-invasive lactate measurement. It could be used to evaluate lactate variation in relation to the anaerobic threshold in endurance sport and for monitoring lactic acidosis in critical-care patients.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Phosphate de sodium dibasic, ACS reagent, ≥99.0%
Sigma-Aldrich
Phosphate de sodium monobasic monohydrate, ACS reagent, ≥98%
Sigma-Aldrich
Chlorure de sodium, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Phosphate de sodium dibasic, puriss. p.a., ACS reagent, anhydrous, ≥99.0% (T)
Sigma-Aldrich
Urée, powder, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Chlorure de sodium solution, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Chlorure de sodium solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Chlorure de sodium, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Phosphate de sodium monobasic monohydrate, BioXtra, for molecular biology, ≥99.5% (T)
Sigma-Aldrich
Phosphate de sodium monobasic monohydrate, puriss. p.a., ACS reagent, ≥99.0% (T)
Sigma-Aldrich
Phosphate de sodium dibasic, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, E 339, anhydrous, 98-100.5% (calc. to the dried substance)
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Supelco
Urea, 8 M (after reconstitution with 16 mL high purity water)
SAFC
Chlorure de sodium solution, 5 M
Sigma-Aldrich
L-histidine monohydrochloride monohydrate, ≥99.0% (AT)
Sigma-Aldrich
Phosphate de sodium dibasic, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99.0%
Sigma-Aldrich
L-histidine monohydrochloride monohydrate, from non-animal source, meets EP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Phosphate de sodium dibasic, for molecular biology, ≥98.5% (titration)
Sigma-Aldrich
Luminol, 97%
Sigma-Aldrich
L-histidine monohydrochloride monohydrate, ≥98% (HPLC)
Sigma-Aldrich
Chlorure de sodium solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Phosphate de sodium dibasique solution, BioUltra, 0.5 M in H2O
Sigma-Aldrich
Chlorure de sodium, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Chlorure de sodium, 99.999% trace metals basis
Sigma-Aldrich
Urée, BioXtra, pH 7.5-9.5 (20 °C, 5 M in H2O)
Sigma-Aldrich
Urée, BioUltra, for molecular biology, 99% (T)
Sigma-Aldrich
Luminol, ≥97% (HPLC)
Sigma-Aldrich
Phosphate de sodium monobasic monohydrate, BioReagent, suitable for electrophoresis, 98.0-102.0%
Sigma-Aldrich
Urée, ACS reagent, 99.0-100.5%
Sigma-Aldrich
Chlorure de sodium, BioXtra, ≥99.5% (AT)