Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

N7261

Sigma-Aldrich

Nortriptyline hydrochloride

≥98% (HPLC), powder

Synonyme(s) :

3-(10,11-Dihydro-5H-dibenzo[a,d]cyclohepten-5-ylidene)-N-methyl-1-propanamine hydrochloride, Desmethylamitriptyline hydrochloride

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C19H21N · HCl
Numéro CAS:
Poids moléculaire :
299.84
Numéro CE :
Numéro MDL:
Code UNSPSC :
41116107
ID de substance PubChem :
Nomenclature NACRES :
NA.77

Niveau de qualité

Pureté

≥98% (HPLC)

Forme

powder

Couleur

white to off-white

Solubilité

ethanol: 100 mg/mL
H2O: soluble

Auteur

Eli Lilly

Chaîne SMILES 

Cl.CNCC\C=C1\c2ccccc2CCc3ccccc13

InChI

1S/C19H21N.ClH/c1-20-14-6-11-19-17-9-4-2-7-15(17)12-13-16-8-3-5-10-18(16)19;/h2-5,7-11,20H,6,12-14H2,1H3;1H

Clé InChI

SHAYBENGXDALFF-UHFFFAOYSA-N

Informations sur le gène

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Actions biochimiques/physiologiques

Tricyclic antidepressant that is a more potent inhibitor of the norepinephrine transporter (Ki = 3.4 nM) than the serotonin transporter (Ki = 161 nM). 5-HT2 serotonin receptor antagonist.

Caractéristiques et avantages

This compound is featured on the Biogenic Amine Transporters page of the Handbook of Receptor Classification and Signal Transduction. To browse other handbook pages, click here.
This compound was developed by Eli Lilly. To browse the list of other pharma-developed compounds and Approved Drugs/Drug Candidates, click here.

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Acute Tox. 4 Oral

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Fabrice Gritti et al.
Journal of chromatography. A, 1282, 58-71 (2013-02-21)
The adsorption behaviors of a neutral (caffeine) and a positively charged compound (nortriptylinium) are investigated on two RPLC/hybrid stationary phases, eluted with a low ionic strength buffer (phosphate buffer, W(S)pH 2.63, I=10mM). The first phase, bridge ethylene hybrid (BEH), is
Rudolf Uher et al.
Depression and anxiety, 29(12), 1043-1049 (2012-08-31)
It has been suggested that clinician-rated scales and self-report questionnaires may be interchangeable in the measurement of depression severity, but it has not been tested whether clinically significant information is lost when assessment is restricted to either clinician-rated or self-report
Aravind Penmatsa et al.
Nature, 503(7474), 85-90 (2013-09-17)
Antidepressants targeting Na(+)/Cl(-)-coupled neurotransmitter uptake define a key therapeutic strategy to treat clinical depression and neuropathic pain. However, identifying the molecular interactions that underlie the pharmacological activity of these transport inhibitors, and thus the mechanism by which the inhibitors lead
Robert A Power et al.
Journal of psychiatric research, 46(10), 1333-1338 (2012-07-10)
Most comparisons of the efficacy of antidepressants have relied on the assumption that missing data are randomly distributed. Dropout rates differ between drugs, suggesting this assumption may not hold true. This paper examines the effect of non-random dropout on a
Matthew T Olson et al.
Clinical chemistry, 59(6), 920-927 (2013-02-22)
The addition of a calibration curve with every run is both time-consuming and expensive for clinical mass spectrometry assays. We present alternative calibration strategies that eliminate the need for a calibration curve except as required by laboratory regulations. We measured

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique