Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

MSCAL3

Supelco

ProteoMass Protein MALDI-MS Calibration Kit

Protein MALDI MS Calibration Standard

Synonyme(s) :

Protein Mass Spectrometry Calibrators

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.24

Gamme de produits

ProteoMass

Niveau de qualité

Qualité

Protein MALDI MS Calibration Standard

Application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

Température de stockage

15-25°C

Application

This kit features a convenient selection of pre-qualified standard proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionization (MALDI) mass spectrometers. Configured specifically for applications in the mass range of 5 to 66 kDa, MSCAL3 is ideal for most protein studies. Applications include calibration, tuning, and sensitivity testing of MALDI instruments from all manufacturers.
ProteoMass Protein MALDI-MS Calibration Kit has been used as a mass calibration standard for MALDI-TOF MS (matrix assisted laser desorption ionization-time of flight mass spectrometry) analysis.

Informations légales

6538 is a trademark of American Type Culture Collection
ProteoMass is a trademark of Sigma-Aldrich Co. LLC

Composants de kit seuls

Réf. du produit
Description

  • Sinapinic acid, Use tested for MALDI-TOF Mass Spec. 8 x 10

Composants de kit également disponibles séparément

Réf. du produit
Description
FDS

  • I6279ProteoMass Insulin MALDI-MS Standard, vial of 10 nmol, monoisotopic mol wt 5,729.6087 Da 2 x 10FDS

  • C8857ProteoMass Cytochrome c MALDI-MS Standard, vial of 10 nmol, (M+H+) 12,361.96 Da by calculation 2 x 10FDS

  • A8971ProteoMass Apomyoglobin MALDI-MS Standard, vial of 10 nmol, (M+H+) 16,952.27 Da by calculation 2 x 10FDS

  • A9096ProteoMass Aldolase MALDI-MS Standard, vial of 10 nmol, average mol wt 39,211.28 Da by calculation 2 x 10FDS

  • A8471ProteoMass Albumin MALDI-MS Standard, vial of 10 nmol, average mol wt 66,429.09 Da by calculation 2 x 10FDS

  • Acetonitrile 30 mL

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 3


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Expression and purification of recombinant apolipoprotein A-I Zaragoza (L144R) and formation of reconstituted HDL particles.
Fiddyment S, et al.
Protein Expression and Purification, 80, 110-116 (2011)
Wipawadee Sianglum et al.
PloS one, 6(2), e16628-e16628 (2011-02-18)
The ethanolic extract from Rhodomyrtus tomentosa leaf exhibited good antibacterial activities against both methicillin-resistant Staphylococcus aureus (MRSA) and S. aureus ATCC 29213. Its minimal inhibitory concentration (MIC) values ranged from 31.25-62.5 µg/ml, and the minimal bactericidal concentration (MBC) was 250
Binding of the N-terminal domain of the lactococcal bacteriophage TP901-1 CI repressor to its target DNA: a crystallography, small angle scattering, and nuclear magnetic resonance study.
Frandsen KH, et al.
Biochemistry, 52, 6892-6904 (2013)
Marta Martínez-Júlvez et al.
The FEBS journal, 279(23), 4306-4317 (2012-10-09)
The RdxA oxygen-insensitive nitroreductase of the human gastric pathogen Helicobacter pylori is responsible for the susceptibility of this organism to the redox active prodrug metronidazole [2-(2-methyl-5-nitro-1H-imidazol-1-yl)ethanol]. Loss-of-function mutations in rdxA are primarily responsible for resistance to this therapeutic. RdxA exhibits potent
Tyler A Zimmerman et al.
Analytical chemistry, 83(15), 6090-6097 (2011-06-23)
In-source decay (ISD) fragmentation as combined with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allows protein sequencing directly from mass spectra. Acquisition of MALDI-ISD mass spectra from tissue samples is achieved using an appropriate MALDI matrix, such as 1,5-diaminonaphthalene (DAN). Recent

Contenu apparenté

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

Afficher tout

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique