Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

MIDCLARET

Sigma-Aldrich

CellVue® Claret Far Red Fluorescent Cell Linker Midi Kit for General Membrane Labeling

Distributed for Phanos Technologies

Synonyme(s) :

Far red membrane probe kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352207
Nomenclature NACRES :
NA.32

Fabricant/nom de marque

Distributed for Phanos Technologies

Niveau de qualité

Conditions de stockage

protect from light

Technique(s)

flow cytometry: suitable

Fluorescence

λex 655 nm; λem 675 nm

Application(s)

cell analysis
detection

Méthode de détection

fluorometric

Conditions d'expédition

ambient

Température de stockage

room temp

Application

CellVue Claret kit fluoresces in the far red and may be used for general cell membrane labeling including in vitro cell labeling, in vitro lymphocyte proliferation studies,† in vivo cytotoxicity assays,† and also as a second color for monitoring cell-cell membrane transfer.†

Actions biochimiques/physiologiques

The CellVue Claret Fluorescent Cell Linker kit uses a proprietary membrane labeling technology to stably incorporate a far red fluorescent dye with long aliphatic tails (CellVue Claret) into lipid regions of the cell membrane.†

Conditionnement

This kit provides enough dye for up to 50 samples of 20 million cells each and enough diluent for up to 30 samples of 20 million cells each when using a 2 mL final staining volume containing a final concentration of 2 x 10-6 M of PKH26 dye. Users must determine the optimal dye and cell concentrations from their cell type(s) and experimental purposes.

Liaison

For additional technical details on Fluorescent Cell Linker Dyes including a comprehensive bibliography, please visit PKH and CellVue®; Claret Fluorescent Cell Linker Dyes.

Informations légales

Distributed for Phanos Technologies, Inc.
Patent Information
CellVue is a registered trademark of Phanos Technologies

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Irrit. 2 - Flam. Liq. 2

Classe de danger pour l'eau (WGK)

WGK 1


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Ryan W S Peacock et al.
Biotechnology and bioengineering, 108(9), 2003-2010 (2011-04-16)
In higher eukaryotes, E2F transcription factors often drive expression of genes necessary for the cell cycle, notably the G1/S phase transition. With conventional transcriptional reporter systems, expression of a reporter gene from an E2F-responsive promoter would allow one to identify
Seishiro Hirano et al.
Toxicology and applied pharmacology, 259(1), 96-103 (2012-01-03)
The toxicity of carbon nanotubes (CNTs), a highly promising nanomaterial, is similar to that of asbestos because both types of particles have a fibrous shape and are biopersistent. Here, we investigated the characteristics of macrophage receptor with collagenous structure (MARCO)
Mercedes Rodriguez Garcia et al.
The Journal of clinical investigation, 120(7), 2486-2496 (2010-06-17)
One of the main unresolved questions in solid organ transplantation is how to establish indefinite graft survival that is free from long-term treatment with immunosuppressive drugs and chronic rejection (i.e., the establishment of tolerance). The failure to achieve this goal
Matthew D Morse et al.
The Prostate, 72(11), 1239-1247 (2012-01-04)
T cells infiltrate the prostates of prostate cancer patients undergoing neoadjuvant androgen deprivation. These prostate-infiltrating T cells have an oligoclonal phenotype, suggesting the development of an antigen-specific T-cell response. We hypothesized that androgen deprivation might elicit a prostate tissue-specific T-cell
Jingting Li et al.
Biomaterials, 35(2), 642-653 (2013-10-24)
Autologous cells suffer from limited cell number and senescence during ex vivo expansion for cartilage repair. Here we found that expansion on extracellular matrix (ECM) deposited by fetal synovium-derived stem cells (SDSCs) (FE) was superior to ECM deposited by adult

Articles

Lipophilic cell tracking dyes enable cancer biologists to track tumor and immune cell functions both in vitro and in vivo. Read the article to choose a right membrane dye kit for cell tracking and proliferation monitoring.

Lipophilic cell tracking dyes enable cancer biologists to track tumor and immune cell functions both in vitro and in vivo. Read the article to choose a right membrane dye kit for cell tracking and proliferation monitoring.

Lipophilic cell tracking dyes enable cancer biologists to track tumor and immune cell functions both in vitro and in vivo. Read the article to choose a right membrane dye kit for cell tracking and proliferation monitoring.

Lipophilic cell tracking dyes enable cancer biologists to track tumor and immune cell functions both in vitro and in vivo. Read the article to choose a right membrane dye kit for cell tracking and proliferation monitoring.

Afficher tout

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique