Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

D0405

Sigma-Aldrich

Dialysis tubing, high retention seamless cellulose tubing

avg. flat width 23 mm (0.9 in.), MWCO 14000, 99.99% retention

Synonyme(s) :

Dialysis tubing

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41123100
Nomenclature NACRES :
NB.22

Diam. moyen

15 mm , when full

Largeur moy. à plat

23 mm (0.9 in.)

Capacité

~50 mL/ft

Dimension de pores

14000 MWCO, 99.99% retention

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Retains >99% of cytochrome c (M.W. 12,400) in solution over a 10-hour period.

Conditionnement

Supplied in rolls, dry

Qualité

May contain glycerin and sulfur compounds in more than trace amounts; washing instructions are included.

Notes préparatoires

Removal of glycerol included as a humectant can be accomplished by washing the tubing in running water for 3-4 hours. Removal of sulfur compounds can be accomplished by treating the tubing with a 0.3% (w/v) solution of sodium sulfide at 80°C for 1 minute. Wash with hot water (60°C) for 2 minutes, followed by acidification with a 0.2% (v/v) solution of sulfuric acid, then rinse with hot water to remove the acid. This tubing will retain most proteins of molecular weight 12,000 or greater.

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Inge Pietersen et al.
Pathogens (Basel, Switzerland), 9(12) (2020-12-03)
Vaccine efficacy requires the production of neutralising antibodies which offer protection against the native virus. The current gold standard for determining the presence of neutralising antibodies is the pseudovirion-based neutralisation assay (PBNA). PBNAs utilise pseudovirions (PsVs), structures which mimic native
Ahmet Dogrul et al.
Journal of microencapsulation, 31(5), 448-460 (2014-04-05)
The purpose of this study was to develop a water/oil microemulsion containing lidocaine hydrochloride (4%) and to compare its local anaesthetic efficacy with commercial products. A pseudoternary diagram (Km:1/1 or 1/2) was constructed using lecithin/ethanol/oil/water. The droplet size, viscosity and
Mojgan Allahyari et al.
Journal of immunological methods, 416, 157-166 (2014-12-02)
Recombinant antigens are increasingly applied to replace native antigens in serological tests. Surface antigen 1 (SAG1) is a highly immunogenic antigen and probably represents the most explored and used antigen of Toxoplasma gondii for development of serological test kits. The

Contenu apparenté

Dialysis Tubing

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique