650579

Sigma-Aldrich

Toluène

HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
C6H5CH3
Numéro CAS:
Poids moléculaire :
92.14
Numéro Beilstein :
635760
Numéro CE :
Numéro MDL:
Code UNSPSC :
12190000
eCl@ss :
39011102
ID de substance PubChem :
Nomenclature NACRES :
NA.06

Qualité

HPLC Plus
for residue analysis

Niveau de qualité

Agence

suitable for EPA 1613

Densité de vapeur

3.2 (vs air)

Pression de vapeur

22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

Pureté

≥99.9%

Forme

liquid

Température d'inflammation spontanée

997 °F

Limite d'explosivité

7 %

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Impuretés

≤0.02% water

Résidus d'évap.

≤0.0001%

Résidus halogénés

<10 ng/L (as heptachlor epoxide)

Indice de réfraction

n/D 1.496 (lit.)

Point d'ébullition

110-111 °C (lit.)
110.6 °C

Pf

-93 °C (lit.)

Densité

0.865 g/mL at 25 °C (lit.)

Absorption UV

λ: 284 nm Amax: 1.00
λ: 300 nm Amax: 0.10
λ: 325 nm Amax: 0.02
λ: 350 nm Amax: 0.005
λ: 400 nm Amax: 0.005

Application(s)

food and beverages

Chaîne SMILES 

Cc1ccccc1

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

Clé InChI

YXFVVABEGXRONW-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Suitable for HPLC, spectrophotometry, environmental testing

Autres remarques

Pesticide Residue Analysis (as Heptachlor Epoxide) <10 ng/L

Produits recommandés

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Pictogrammes

FlameHealth hazardExclamation mark

Mention d'avertissement

Danger

Classification des risques

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Organes cibles

Central nervous system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

39.9 °F - closed cup

Point d'éclair (°C)

4.4 °C - closed cup


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Slide 1 of 2

1 of 2

Analysis of Malondialdehyde, Chlorophyll Proline, Soluble Sugar, and Glutathione Content in Arabidopsis seedling.
Zhang Z and Huang R.
Bio-protocol, 3(14) (2013)
Sheng-Suan Cai et al.
Journal of chromatography. A, 1173(1-2), 88-97 (2007-10-30)
In this work, we evaluate the performance of liquid chromatography-atmospheric pressure photoionization-mass spectrometry (LC-APPI-MS) for non-aqueous reversed phase analysis of six triacylglycerol model compounds using six binary mobile phases including MeOH/iPrOH, MeOH/CHCl(3), MeOH/CH(2)Cl(2), CH(3)CN/iPrOH, CH(3)CN/CHCl(3), and CH(3)CN/CH(2)Cl(2). All mobile phases
Structural study on syndiotactic polystyrene: 2. Crystal structure of molecular compound with toluene.
Chatani Y, et al.
Polymer, 34(8), 1620-1620 (1993)
T Biegert et al.
European journal of biochemistry, 238(3), 661-668 (1996-06-15)
Toluene is degraded anoxically to CO2 by the denitrifying bacterium Thauera aromatica. Toluene first becomes oxidized to benzoyl-CoA by O2-independent reactions. Benzoyl-CoA is then reduced to non-aromatic products by benzoyl-CoA reductase. We set out to study the reactions employed for
V Melissinaki et al.
Biofabrication, 3(4), 045005-045005 (2011-09-21)
This study reports on the production of high-resolution 3D structures of polylactide-based materials via multi-photon polymerization and explores their use as neural tissue engineering scaffolds. To achieve this, a liquid polylactide resin was synthesized in house and rendered photocurable via

Protocoles

A guide to create solvent systems used for the thin-layer chromatography assay of Novabiochem products.

A guide to create solvent systems used for the thin-layer chromatography assay of Novabiochem products.

A guide to create solvent systems used for the thin-layer chromatography assay of Novabiochem products.

A guide to create solvent systems used for the thin-layer chromatography assay of Novabiochem products.

Contenu apparenté

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique