Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

MAGPMAG-24K

Millipore

MILLIPLEX® Mouse Angiogenesis/Growth Factor Magnetic Bead Panel - Cancer Multiplex Assay

for the simultaneous quantification of multiple analytes

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.84

Niveau de qualité

Espèces réactives

mouse

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 90-104%
standard curve range: 1-1,000 pg/mL
(Endothelin-1)

standard curve range: 137-100,000 pg/mL
(Follistatin)

standard curve range: 137-100,000 pg/mL
(HGF)

standard curve range: 137-100,000 pg/mL
(SDF-1)

standard curve range: 14-10,000 pg/mL
(IL-1b)

standard curve range: 14-10,000 pg/mL
(Leptin)

standard curve range: 14-10,000 pg/mL
(MIP-1α)

standard curve range: 14-10,000 pg/mL
(sALK-1)

standard curve range: 14-10,000 pg/mL
(sCD31/ PECAM-1)

standard curve range: 27-20,000 pg/mL
(Angiopoietin-2)

standard curve range: 27-20,000 pg/mL
(EGF)

standard curve range: 27-20,000 pg/mL
(Endoglin)

standard curve range: 27-20,000 pg/mL
(MCP-1)

standard curve range: 27-20,000 pg/mL
(VEGF-C)

standard curve range: 3-2,000 pg/mL
(PLGF-2)

standard curve range: 6-4,000 pg/mL
(TNFα)

standard curve range: 6-4,000 pg/mL
(VEGF-A)

standard curve range: 69-50,000 pg/mL
(FGF-2/FGF-basic)

standard curve range: 69-50,000 pg/mL
(Prolactin)

standard curve range: 69-50,000 pg/mL
(VEGF-D)

standard curve range: 69-50,000 pg/mL
(sFasL)

standard curve range: 7-5,000 pg/mL
(Amphiregulin)

standard curve range: 7-5,000 pg/mL
(Betacellulin)

standard curve range: 7-5,000 pg/mL
(G-CSF)

standard curve range: 7-5,000 pg/mL
(IL-17A)

standard curve range: 7-5,000 pg/mL
(IL-6)

standard curve range: 7-5,000 pg/mL
(KC/CXCL1)

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Description générale

Angiogenesis, the development of new vascular networks, is a key process in normal growth and development as well as in wound healing, with homeostasis maintained by a delicate balance of angiogenic factors and inhibitors. Consequently, insufficient, or excessive blood vessel growth underlies many diseases, including cardiovascular disease, diabetic ulcers, macular degeneration, and cancer. Angiogenesis plays a significant role in tumor growth and metastasis.

MILLIPLEX® Mouse Angiogenesis//Growth Factor Panel, is a 24-plex (for serum/plasma) or 27-plex (for cell culture) kit to be used for the simultaneous quantification of the following analytes: Angiopoietin-2, G-CSF, sFasL, sAlk-1, Amphiregulin, Leptin, IL-1b, Betacellulin, EGF, IL-6, Endoglin, Endothelin-1, FGF-2, Follistatin, HGF, PECAM-1, IL-17, PLGF-2, KC, MCP-1, Prolactin, MIP-1a, SDF-1, VEGF-C, VEGF-D, VEGF-A, and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Circulating Cancer

Spécificité

Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Application

  • Analytes: sALK-1, Amphiregulin, Angiopoietin-2, Betacellulin, sCD31/sPECAM-1, EGF, Endoglin, Endothelin-1, sFasL, FGF-2 (FGF-basic), Follistatin (FST), G-CSF, HGF, IL-1β, IL-6, IL-17A (CTLA8), KC (GRO/CINC-1/CXCL1), Leptin, MCP-1 (CCL2), MIP-1α (CCL3), Placental Growth Factor 2 (PLGF-2), Prolactin, SDF-1 (CXCL12), TNF-α, VEGF-A, VEGF-C, VEGF-D
  • NOTE: Angiopoeitin-2, Betacellulin, and PECAM-1 should not be run in serum/plasma samples
  • Recommended Sample Type: Mouse serum, plasma or tissue/cell culture supernatants or lysates
  • Recommended Sample Dilution: 25 μL per well of diluted serum or plasma; cell/tissue culture samples may require diltion in appropriate control medium
  • Assay Run Time: Overnight (16-20 hours) at 2-8°C
  • Research Category: Cancer

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

Everything you need in a single kit.

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Autres remarques

Please note: Sample Type must be selected when configuring this kit. Angiopoeitin-2, Betacellulin, and PECAM-1 should not be run in serum/plasma samples.
Sensitivity: Refer to kit protocol for sensitivities of individual analytes.

Informations légales

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organes cibles

Respiratory Tract

Code de la classe de stockage

10 - Combustible liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Sneha Sundaram et al.
Anticancer research, 39(4), 1729-1738 (2019-04-07)
Monocyte chemotactic protein-1 (MCP1) is a potent adipokine. This study tested the hypothesis that adipose-produced MCP1 contributes to metastasis. In a spontaneous metastasis model of Lewis lung carcinoma (LLC), male adipose MCP1-deficient (Mcp1-/-) and wild-type (WT) mice were fed the
Kenny Schlosser et al.
Thorax, 73(3), 248-261 (2017-09-28)
Elevated plasma levels of angiopoietin-2 (ANGPT2) have been reported in patients with acute lung injury (ALI); however, it remains unclear whether this increase contributes to, or just marks, the underlying vasculopathic inflammation and leak associated with ALI. Here we investigated
Wenjie Li et al.
Stem cells international, 2022, 8540535-8540535 (2022-06-18)
Adipose-derived stem cells (ASCs) improve the self-renewal and survival of fat grafts in breast reconstruction after oncology surgery. However, ASCs have also been found to enhance breast cancer growth, and its role in tumor proliferation remains largely elusive. Here, we
Aziza R Alrafiah
Biomedicines, 9(9) (2021-09-29)
The present study focused on secondary injury following the middle cerebral artery (MCA) occlusion in rats not linked to the MCA's feeding zone. This entity has been very rarely studied. Additionally, this study investigated the rates of expression of five
Pier-Anne Lachance et al.
PloS one, 8(9), e76078-e76078 (2013-10-03)
During acute inflammation, functioning lymphatics are believed to reduce edema and to provide a transiting route for immune cells, but the extent at which the dermal lymphatic remodeling impacts lymphatic transport or the factors regulating these changes remains unclear. Herein

Contenu apparenté

MILLIPLEX® panel enables efficient angiogenesis biomarker quantification for NSCLC metastatic progression correlation.

MILLIPLEX® panel enables efficient angiogenesis biomarker quantification for NSCLC metastatic progression correlation.

MILLIPLEX® panel enables efficient angiogenesis biomarker quantification for NSCLC metastatic progression correlation.

MILLIPLEX® panel enables efficient angiogenesis biomarker quantification for NSCLC metastatic progression correlation.

Afficher tout

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique