C-113
Cortisol-D4 (9,11,12, 12-D4) solution
100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Synonyme(s) :
Cortisol-D4 (9,11,12,12-D4) solution, Hydrocortisone-9,11,12,12-D4 solution
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
100 μg/mL in methanol
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
clinical testing
clinical testing
Format
single component solution
Température de stockage
−20°C
Chaîne SMILES
[2H]C1([2H])[C@]([2H])(O)[C@@]2([2H])[C@@H](CCC3=CC(=O)CC[C@]23C)[C@@H]4CCC(O)(C(=O)CO)[C@@]14C
InChI
1S/C21H30O5/c1-19-7-5-13(23)9-12(19)3-4-14-15-6-8-21(26,17(25)11-22)20(15,2)10-16(24)18(14)19/h9,14-16,18,22,24,26H,3-8,10-11H2,1-2H3/t14-,15-,16-,18+,19-,20-,21-/m0/s1/i10D2,16D,18D
Clé InChI
JYGXADMDTFJGBT-BJJKTIQHSA-N
Description générale
Application
- Identification of cortisol by atmospheric pressure chemical ionization (APCI) and selected reaction monitoring (SRM) during the high-performance liquid chromatography- tandem mass spectrometric (HPLC-MS/MS) analysis of cortisol in human sweat samples
- Combined determination of cortisol and cortisone in 48 serum samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Development and validation of an LC-MS/MS method to determine five steroids― free cortisol, cortisone, tetrahydrocortisol, allo-tetrahydrocortisol, and tetrahydrocortisone in urine samples
- Multi-residue analysis of cortisol, cortisone, and dehydroepiandrosterone sulfate (DHEAS) in 103 hair samples by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS)
- Rapid LC-MS/MS-based assay of cortisol in 2860 serum samples over a duration of one year, using a simple protein precipitation technique for sample preparation
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique