To neutralize 0.5 L of 120 mM 66930 solution, it is recommended to use 8 ml of 0.5 N HCl to adjust the pH to 8, and then dilute the HCl (e.g. 0.1 N) to titrate to pH 7.3. This approach can help avoid the drastic drop in pH.
66930
N-Methyl-D-glucamine
ReagentPlus®, ≥99.0% (T)
Synonym(s):
1-Deoxy-1-(methylamino)-D-glucitol, Meglumine
About This Item
Recommended Products
biological source
synthetic
Quality Level
product line
ReagentPlus®
Assay
≥99.0% (T)
form
powder
optical activity
[α]20/D −16.5±0.5°, c = 2% in H2O
autoignition temp.
~662 °F
mp
126-131 °C
129-131.5 °C (lit.)
solubility
H2O: 0.1 g/mL, clear, colorless
anion traces
chloride (Cl-): ≤50 mg/kg
phosphate (PO43-): ≤5 mg/kg
sulfate (SO42-): ≤50 mg/kg
cation traces
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Mo: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤20 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg
SMILES string
CNC[C@H](O)[C@@H](O)[C@H](O)[C@H](O)CO
InChI
1S/C7H17NO5/c1-8-2-4(10)6(12)7(13)5(11)3-9/h4-13H,2-3H2,1H3/t4-,5+,6+,7+/m0/s1
InChI key
MBBZMMPHUWSWHV-BDVNFPICSA-N
Looking for similar products? Visit Product Comparison Guide
General description
Application
Legal Information
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
-
What is the optimal volume of HCl to use in order to achieve a pH of 7.3 when using N-Methyl-D-glucamine (P/N: 66930) in a patch clamp solution without adding any additional Na+ ions?
1 answer-
Helpful?
-
-
When preparing a solution for patch clamping, what is the best optimal amount of HCL to use for ensuring that NaOH will not be required to maintain pH 7.3? F
1 answer-
The necessary amount of HCl would need to be determined by the end-user. It is recommended to record the initial pH value prior to the addition of HCl. After recording the intial pH, add small increments of HCl (1-2 mL). The molarity of the HCL must also be considered when adding incremental volumes. A 1M HCl would be considered fairly dilute. Higher concentrations would require volume adjustments. Record the pH value after 5 minutes of stirring.
For further questions or concerns, please navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquiries" under the Products Section with all the required information so that a member of the Technical Service team can reach out to assist further. Thank you.