Skip to Content
Merck

Skip To

T5941

Trizma® hydrochloride

BioPerformance Certified, suitable for cell culture, ≥99.0% (titration)

Synonym(s):

TRIS HCl, TRIS hydrochloride, Tris(hydroxymethyl)aminomethane hydrochloride, Tromethane hydrochloride

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

Linear Formula:
NH2C(CH2OH)3 · HCl
CAS Number:
Molecular Weight:
157.60
UNSPSC Code:
12161700
NACRES:
NA.25
PubChem Substance ID:
EC Number:
214-684-5
Beilstein/REAXYS Number:
3675235
MDL number:
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

grade

BioPerformance Certified

assay

≥99.0% (titration)

form

crystalline powder

technique(s)

DNA purification: suitable, cell culture | mammalian: suitable, electrophoresis: suitable, protein extraction: suitable

impurities

DNAse, Exonuclease; NICKase, Endonuclease; RNAse and Protease, none detected, endotoxin and total aerobic microbial count, tested, ≤0.5% water (Karl Fischer)

color

white

useful pH range

7.0-9.0

pKa (25 °C)

8.1

mp

150-152 °C

solubility

H2O: 667 mg/mL

density

1.39 g/cm3 at 20—25 °C, 1.40 g/cm3 at 20—25 °C

absorption

≤0.05 at 290 at 40%

suitability

suitable for electrophoresis, suitable for immunohistochemistry, suitable for molecular biology

application(s)

diagnostic assay manufacturing
general analytical
life science and biopharma
sample preparation

SMILES string

Cl.NC(CO)(CO)CO

InChI

1S/C4H11NO3.ClH/c5-4(1-6,2-7)3-8;/h6-8H,1-3,5H2;1H

InChI key

QKNYBSVHEMOAJP-UHFFFAOYSA-N

General description

Tris HCl, also known as Trizma® hydrochloride, is a widely used acidic buffer for preparing buffers within the physiological pH range of 7.3 to 7.5. With a pKa of 8.08 at 25°C, Tris HCl offers a pH range of 7.0 to 9.0, matching the typical pH of living organisms. As a result, Tris HCl is an essential component of buffer solutions used in various biological, cell culture, biochemistry, and molecular biology applications. It is important to note that neither Tris base nor Tris hydrochloride on their own can provide sufficient buffering capacity. Therefore, they are typically combined to create a buffer within the pH range of 7 to 9, ensuring effective pH control.

Tris buffers are indispensable in techniques like protein electrophoresis and western blotting. In many western blot protocols, a low ionic strength Tris buffer is employed for protein transfer. The transfer duration depends on the blotting apparatus and the size range of peptides under investigation. Tris-based buffers are also commonly used in SDS-PAGE gels, running buffers, and blotting buffers.

Furthermore, Tris salts find extensive use in DNA agarose electrophoresis, particularly in the preparation of buffers like TAE (Tris acetate/EDTA) and TBE (Tris borate/EDTA). These buffers play a pivotal role in various applications, including biochemistry, protein purification, and electrophoresis. Tris HCl is a versatile and essential for maintaining the pH of biological systems and ensuring the optimal performance of biochemical, cell culture, and molecular biology techniques.

Application

Tris-HCl hasbenn used
  • as a washing and rinsing buffer in an immunohistochemical analysis(1)
  • as a component of reducing sample buffer, lysis buffer and elution buffer, in a biochemical research involving gel electrophoresis and BioLayer interferometry measurement(2)

Features and Benefits

  • Suitable for Molecular Biology and Cell Culture
  • Can be used as a Buffer component, for Electrophoresis and Protein separation
  • Tested for Endotoxins and Total Aerobic Microbial Count
  • Free from DNase, NICKase, RNase, and Protease
  • Tested to confirm low levels of heavy metal contamination, ensuring suitability for various applications
  • Effective Buffering from pH 7-9 (25 °C) with a pKa of 8.1 (25 °C)
  • Highly soluble in water

Packaging

T5941-1KT:
Each kit contains 3 x 100G samples, each sample from a uniquely manufactured lot.

Other Notes

For additional information on our range of Biochemicals, please complete this form.
The pH values of all buffers are temperature and concentration dependent. For Tris buffers, pH increases about 0.03 unit per °C decrease in temperature, and decreases 0.03-0.05 unit per ten-fold dilution. For precise applications, use a carefully calibrated pH meter with a glass/calomel combination electrode.

Legal Information

Trizma is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
T3253T15760SBR00051
technique(s)

DNA purification: suitable, electrophoresis: suitable, cell culture | mammalian: suitable, protein extraction: suitable

technique(s)

affinity chromatography: suitable

technique(s)

-

technique(s)

-

assay

≥99.0% (titration)

assay

≥99.0% (titration)

assay

≥99%

assay

-

grade

BioPerformance Certified

grade

reagent grade

grade

reagent grade

grade

-

Quality Level

400

Quality Level

400

Quality Level

200

Quality Level

200

application(s)

diagnostic assay manufacturing
general analytical
life science and biopharma
sample preparation

application(s)

diagnostic assay manufacturing
life science and biopharma
sample preparation

application(s)

-

application(s)

-

form

crystalline powder

form

crystalline

form

crystalline

form

-


Still not finding the right product?

Explore all of our products under Trizma® hydrochloride


Storage Class

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters