GC Analysis of PCBs in Transformer Oil on a 5% Phenyl Column after SPE using Supelclean™ Sulfoxide
suitable for GC, application for SPE
About This Item
technique(s)
gas chromatography (GC): suitable
solid phase extraction (SPE): suitable
test parameters
SPE tube/cartridge: Supelclean Sulfoxide SPE Tube, Glass 6 g/20 mL (55252-U)
sample preparation: SPE (Solid Phase Extraction)
column: 5% phenyl polysiloxane (Supelco equivalent, SLB-5ms, 28471-U)
sample addition: transformer oil spiked with PCBs
detector: QMS (For full method details, please see reference (1))
extraction process: Sample Pre-treatment: paraffin oil was spiked with a Kanechlor PCB mix at the total levels of 3.7 ppm (mg/kg) and diluted with hexane (1:1 v/v). (Commercial insulation oil (Japan Industrial Standard JIS C2320-1999, insulating oil, Class 1-2/4).)
condition: 20 mL acetone; 40 mL of hexane
sample addition: 0.4 mL diluted oil sample
elution: 12 mL hexane (elutes oil interferences); 25 mL hexane (elutes PCBs)
eluate post-treatment: concentrate under nitrogen
suitability
application for SPE
application(s)
environmental
Application
Commercial insulation oil (Japan Industrial Standard JIS C2320-1999, insulating oil, Class 1-2/4, paraffin oil) was spiked with a Kanechlor PCB mix at the total levels of 3.7 ppm (mg/kg) and diluted with hexane (1:1 v/v).
Legal Information
SPE tube or plate
analytical column
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Sorry, we don't have COAs for this product available online at this time.
If you need assistance, please contact Customer Support.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service