Key Documents

10357

Supelco

Amberlite XAD®-2

pkg of 500 g

Sign Into View Organizational & Contract Pricing

Select a Size

500 G
£141.00

£141.00


Please contact Customer Service for Availability

Request a Bulk Order

Select a Size

Change View
500 G
£141.00

About This Item

CAS Number:
MDL number:
UNSPSC Code:
23151817

£141.00


Please contact Customer Service for Availability

Request a Bulk Order

Agency

suitable for ASTM® D4861
suitable for EPA Method 10A, Method 23 and OTM-45

Quality Level

form

beads (small)

packaging

pkg of 500 g

technique(s)

HPLC: suitable
LPLC: suitable

surface area

~300 m2/g

matrix

styrene-divinylbenzene (macroreticular)

matrix active group

polymer

particle size

20-60 mesh

pore size

~0.65 mL/g pore volume
90 Å mean pore size

density

1.02 g/mL at 25 °C (true wet)(lit.)
1.08 g/mL at 25 °C (skeletal)(lit.)

separation technique

reversed phase

storage temp.

2-8°C

SMILES string

N([C@@H](CCC(=O)OC(C)(C)C)C=O)C(=O)OCC1c2c(cccc2)c3c1cccc3

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI key

BCIPGSZQUDLGSY-INIZCTEOSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Amberlite XAD-2, a hydrophobic copolymer of styrene-divinylbenzene resin, requires longer purification process and is used as a sorbent. Amberlite XAD-2 resin depending upon the aromaticity and size of the hydrophobic groups sorbs organic compounds through low-energy physical interactions.[1]
Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.
Specifications:

Application

Amberlite XAD®-2 was used:
  • as adsorbent in the extraction of organochlorine compounds using Soxhlat extraction technique[1]
  • as adsorbent in the extraction of honey samples using column chromatography for HPLC analysis[2]
  • in adsorption chromatography[3]
Polyaromatic adsorbent resin for hydrophobic compounds up to MW 20,000: phenols, organic removal, surfactants, aroma compounds, antibiotic recovery. May be used as support for catalyst or metals removal. For cleaned US EPA versions, see Supelpak-2 and Supelpak-2B.
     

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Amberlite is a trademark of DuPont de Nemours, Inc.
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

related product

Product No.
Description
Pricing

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Trapping efficiency of polyurethane foam and Amberlite XAD-2 for various organochlorine compounds
Nerin, C., et al.
Fresenius Journal of Analytical Chemistry, 352, 609-611 (1995)
M Tamura et al.
The Journal of biological chemistry, 260(17), 9672-9677 (1985-08-15)
Na+,K+-ATPase inhibitors have been found to exist in acutely saline-infused hog plasma, which also inhibit the specific binding of ouabain to Na+,K+-ATPase and the binding of digoxin to specific anti-digoxin antibody. Two of these inhibitors were purified by a combination
I Martos et al.
Journal of agricultural and food chemistry, 48(5), 1498-1502 (2000-05-23)
European Eucalyptus honeys showed a common and characteristic HPLC profile in which the flavonoids myricetin (3,5,7,3',4', 5'-hexahydroxyflavone), tricetin (5,7,3',4',5'-pentahydroxyflavone), quercetin (3,5,7,3',4'-pentahydroxyflavone), luteolin (5,7,3', 4'-tetrahydroxyflavone), and kaempferol (3,5,7, 4'-tetrahydroxyflavone) were identified. Their contents, and relative amounts, in the analyzed honey samples
Vinod K Jain et al.
Talanta, 79(5), 1331-1340 (2009-07-29)
Two novel azocalix[4]pyrrole Amberlite XAD-2 polymeric chelating resins were synthesized by covalently linking diazotized Amberlite XAD-2 with calix[4]pyrrole macrocycles. The chelating resins were used for extraction, preconcentration and sequential separation of metal ions such as Cu(II), Zn(II) and Cd(II) by
Ayako Kanno et al.
The Journal of toxicological sciences, 35(6), 817-826 (2010-12-09)
Amberlite XAD-2 resin extracts of river and drinking water sampled from the Northwest district of Chiba Prefecture in each month during the period from January to December 2008 were investigated to characterize and determine their mutagenic potentials and polycyclic aromatic

Related Content

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

Questions

1–7 of 7 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the most approriate protocol to wash Amberlite before use? Thanks in advance!

    1 answer
    1. Amberlite XAD-2 is a crude preparation and must be thoroughly cleaned prior to use.

      1. Rinse with hot deionized water (may hold in nylon filter cloth to retain particles) - use at least 3 bed volumes per hour at 110 deg C
      2. Soak overnight in 2 bed volumes (BV) of ethanol.
      3. Load resin into a glass column and rinsed with a further 2 BV of ethanol.
      4. Rinse with 2 BV of deionized water to remove the ethanol, 1 BV of 4% (w/v) sodium hydroxide, 2 BV of deionized water, 1 BV 4% (v/v) hydrochloric acid, and finally rinse with deionized water until the pH of the eluent is neutral.

      For further use it is advantageous to do a wash in the same solvent use in the application.
      Store in sealed container; may be refrigerated but NOT frozen. As a bacteriostat, one may rinse with 20% ethanol (deionized water) prior to storage.

      Helpful?

  4. May I purchase Amberlite XAD-2 in large quantities?

    1 answer
    1. The largest package size of Amberlite XAD2 is 25 kg (Product No. 3025-U).

      Helpful?

  5. Is Amberlite XAD-2 ready-to-use?

    1 answer
    1. No.  Amberlite XAD2 is shipped imbibed with 5% NaCl & 1% NaCO3; it has not been specially processed nor cleaned. We suggest that it be extensively treated to a suitable preliminary elution and wash.

      Helpful?

  6. Do you offer a precleaned Amberlite XAD-2?

    1 answer
    1. Yes.  Supelco cleans Amberlite XAD2 for a variety of environmental applications.

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?