Quantification of neurosteroids during pregnancy using selective ion monitoring mass spectrometry.

Steroids (2014-12-30)
Kurt D Pennell, Mark A Woodin, Page B Pennell
RÉSUMÉ

Analytical techniques used to quantify neurosteroids in biological samples are often compromised by non-specificity and limited dynamic range which can result in erroneous results. A relatively rapid and inexpensive gas chromatography-mass spectrometry (GC-MS) was developed to simultaneously measure nine neurosteroids, including allopregnanolone, estradiol, and progesterone, as well as 25-hydroxy-vitamin D3 in plasma samples collected from adult women subjects during and after pregnancy. Sample preparation involved solid-phase extraction and derivatization, followed by automated injection on a GC equipped with a mass selective detector (MSD) operated in single ion monitoring (SIM) mode to yield a run time of less than 11min. Method detection limits for all neurosteroids ranged from 30 to 200pg/mL (parts per trillion), with coefficients of variation that ranged from 3% to 5% based on intra-assay comparisons run in triplicate. Although concentrations of estradiol measured by chemiluminescent immunoassay (CIA) were consistent with values determined by GC-MS values, CIA yielded considerable higher values of progesterone, suggesting antibody cross reactions resulting from low specificity. Mean neurosteroid levels and representative time-course data demonstrate the ability of the method to quantify changes in multiple neurosteroids during pregnancy, including rapid declines in neurosteroid levels associated with delivery. This simplified GC-MS method holds particular promise for research and clinical laboratories that require simultaneous quantification of multiple neurosteroids, but lack the resources and expertise to support advanced liquid chromatography-tandem mass spectrometry facilities.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Dichlorométhane, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Dichlorométhane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Dichlorométhane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Dichlorométhane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Supelco
N,O-Bis(triméthylsilyl)trifluoroacétamide avec triméthylchlorosilane, with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
N,O-Bis(triméthylsilyl)trifluoroacétamide, ≥99%
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Progesterone, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
Progesterone, ≥99%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acétonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Dichlorométhane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
β-Estradiol, meets USP testing specifications
Sigma-Aldrich
Dichlorométhane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Estrone, ≥99%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
trans-Dehydroandrosterone, ≥99%