Accéder au contenu
Merck

PET imaging of Oatp-mediated hepatobiliary transport of [(11)C] rosuvastatin in the rat.

Molecular pharmaceutics (2014-06-25)
Jiake He, Yang Yu, Bhagwat Prasad, Jeanne Link, Robert S Miyaoka, Xijing Chen, Jashvant D Unadkat
RÉSUMÉ

A novel positron emission tomography (PET) tracer, [(11)C]-rosuvastatin (RSV), was developed to dynamically and noninvasively measure hepatobiliary transport and tissue distribution of [(11)C]-RSV in rats. Male Sprague-Dawley rats were administered either an Oatp inhibitor, rifampin (RIF, 40 mg/kg iv bolus plus 1.85 mg/min/kg iv infusion, n = 3), or the corresponding vehicle (saline, n = 3) for at least 90 min. Then, while these infusions were ongoing, the animals received [(11)C]-rosuvastatin (∼1 mCi/30 s, iv infusion). After [(11)C]-RSV administration, the lower abdominal region of the rats was imaged for 90 min. Time-activity curves for liver, intestine, and kidney were obtained and corrected for vascular content prior to noncompartmental and compartmental (five-compartment model) analysis. The majority of the [(11)C]-RSV dose was distributed into the liver. In the presence of RIF, the area under the [(11)C]-RSV radioactivity blood concentration-time profile (AUC0-90 min) was increased by ∼3-fold. Relative to the control animals, RIF reduced the distribution of [(11)C]-RSV radioactivity into the liver and kidney (tissue AUC0-15 min/blood AUC0-15 min) by 54% and 73% respectively. Compartmental modeling showed that RIF decreased CLBL, CLLI, CLBK, and CLK0 but had no effect on CLLB, where B, L, I, K, and 0 represent blood, liver, intestine, kidney, and irreversible loss. [(11)C]-RSV can be used to dynamically and noninvasively quantify hepatobiliary transport and hepatic concentration of the drug, in the absence and presence of drug interactions, in rats and could be used for the same purpose in humans.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Formate d′ammonium, reagent grade, 97%
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Formate d′ammonium, ≥99.995% trace metals basis
Sigma-Aldrich
Acide formique, ACS reagent, ≥88%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acétonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Supelco
Diazepam solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Diazepam
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Acide formique, ≥95%, FCC, FG
Supelco
Formate d′ammonium, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Acétonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acétonitrile, electronic grade, 99.999% trace metals basis