Accéder au contenu
Merck
  • Development of a new cucumber reference material for pesticide residue analysis: feasibility study for material processing, homogeneity and stability assessment.

Development of a new cucumber reference material for pesticide residue analysis: feasibility study for material processing, homogeneity and stability assessment.

Analytical and bioanalytical chemistry (2015-01-30)
Susana Grimalt, Stefan Harbeck, Penka Shegunova, John Seghers, Berit Sejerøe-Olsen, Håkan Emteborg, Marta Dabrio
RÉSUMÉ

The feasibility of the production of a reference material for pesticide residue analysis in a cucumber matrix was investigated. Cucumber was spiked at 0.075 mg/kg with each of the 15 selected pesticides (acetamiprid, azoxystrobin, carbendazim, chlorpyrifos, cypermethrin, diazinon, (α + β)-endosulfan, fenitrothion, imazalil, imidacloprid, iprodione, malathion, methomyl, tebuconazole and thiabendazole) respectively. Three different strategies were considered for processing the material, based on the physicochemical properties of the vegetable and the target pesticides. As a result, a frozen spiked slurry of fresh cucumber, a spiked freeze-dried cucumber powder and a freeze-dried cucumber powder spiked by spraying the powder were studied. The effects of processing and aspects related to the reconstitution of the material were evaluated by monitoring the pesticide levels in the three materials. Two separate analytical methods based on LC-MS/MS and GC-MS/MS were developed and validated in-house. The spiked freeze-dried cucumber powder was selected as the most feasible material and more exhaustive studies on homogeneity and stability of the pesticide residues in the matrix were carried out. The results suggested that the between-unit homogeneity was satisfactory with a sample intake of dried material as low as 0.1 g. A 9-week isochronous stability study was undertaken at -20 °C, 4 °C and 18 °C, with -70 °C designated as the reference temperature. The pesticides tested exhibited adequate stability at -20 °C during the 9-week period as well as at -70 °C for a period of 18 months. These results constitute a good basis for the development of a new candidate reference material for selected pesticides in a cucumber matrix.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétate d'éthyle, ACS reagent, ≥99.5%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Sulfate de sodium, ACS reagent, ≥99.0%, anhydrous, granular
Sigma-Aldrich
Acétate d'éthyle, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Toluène, ACS reagent, ≥99.5%
Sigma-Aldrich
Sulfate de sodium, ACS reagent, ≥99.0%, anhydrous, powder
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétate d'éthyle, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Toluène, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Cyclohexane, ACS reagent, ≥99%
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Cyclohexane, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Toluène, anhydrous, 99.8%
Sigma-Aldrich
Acétate d'éthyle, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Acétate d′ammonium, for molecular biology, ≥98%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Sulfate de sodium, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Acétate d′ammonium solution, for molecular biology, 7.5 M
Sigma-Aldrich
Méthanol, anhydrous, 99.8%