Accéder au contenu
Merck
  • Simultaneous determination of metolazone and losartan potassium in their binary mixtures using high-performance liquid chromatography with fluorimetric detection: application to combined tablets and spiked human plasma.

Simultaneous determination of metolazone and losartan potassium in their binary mixtures using high-performance liquid chromatography with fluorimetric detection: application to combined tablets and spiked human plasma.

Luminescence : the journal of biological and chemical luminescence (2013-09-03)
Mohammed I Walash, Nahed M El-Enany, Manal I Eid, Mona E Fathy
RÉSUMÉ

A new, specific and sensitive reversed-phase high-performance liquid chromatography method was developed for the simultaneous determination of metolazone (MET) and losartan potassium (LOS). Good chromatographic separation was achieved within 6.0 min on a 150 × 4.6 mm i.d., 5 µm Waters, Ireland and ProDIGY 5 ODS 3 100 A column. A mobile phase containing a mixture of methanol and 0.02 M phosphate buffer (65:35, v/v) at pH 3.0 was used. The analysis was performed at a flow rate of 1 mL/min with fluorescence detection at 410 nm after excitation at 230 nm. Aspirin (ASP) was used as an internal standard. The proposed method was rectilinear over 2.0-40.0 (MET) and 40.0-800.0 ng/mL (LOS), with limits of detection of 0.22 and 4.52 ng/mL and limits of quantification of 0.68 and 13.70 ng/mL for MET and LOS, respectively. The method was successfully applied for the simultaneous analysis of the studied drugs in their laboratory-prepared mixtures, single tablets and co-formulated tablets. Moreover, the method was applied to an in vitro drug release (dissolution) test. The method was further extended to the determination of LOS in spiked human plasma. Statistical evaluation and comparison of data obtained using the proposed and comparison methods revealed no significant difference between the two methods in addition to good accuracy and precision for the proposed method.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Dodécylsulfate de sodium, BioReagent, suitable for electrophoresis, for molecular biology, ≥98.5% (GC)
Sigma-Aldrich
1-Propanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Dodécylsulfate de sodium, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
Dodécylsulfate de sodium solution, BioUltra, for molecular biology, 10% in H2O
Sigma-Aldrich
Dodécylsulfate de sodium solution, BioUltra, for molecular biology, 20% in H2O
Sigma-Aldrich
Dodécylsulfate de sodium, BioUltra, for molecular biology, ≥99.0% (GC)
Supelco
Dodécylsulfate de sodium, dust-free pellets, suitable for electrophoresis, for molecular biology, ≥99.0% (GC)
Sigma-Aldrich
Dodécylsulfate de sodium, ≥98.0% (GC)
Sigma-Aldrich
Dodécylsulfate de sodium, ACS reagent, ≥99.0%
Sigma-Aldrich
1-Propanol, ≥99%, FG
Sigma-Aldrich
Dodécylsulfate de sodium, ReagentPlus®, ≥98.5% (GC)
Sigma-Aldrich
Dodécylsulfate de sodium, tested according to NF, mixture of sodium alkyl sulfates consisting mainly of sodium dodecyl sulfate
USP
1-Propanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
1-Propanol, natural, ≥98%, FG
Supelco
1-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Dodécylsulfate de sodium, BioXtra, ≥99.0% (GC)
Sigma-Aldrich
Dodécylsulfate de sodium, 92.5-100.5% based on total alkyl sulfate content basis
Supelco
Dodécylsulfate de sodium, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Dodécylsulfate de sodium, ≥98.0% (GC)
Supelco
1-Propanol, analytical standard
Sigma-Aldrich
Dodécylsulfate de sodium, ≥90% ((Assay))
Sigma-Aldrich
Metolazone, ≥98% (HPLC), solid
Laurilsulfate de sodium, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Dodécylsulfate de sodium, BioReagent, suitable for electrophoresis, for molecular biology, ≥98.5% (GC), free-flowing, Redi-Dri
Metolazone for system suitability, European Pharmacopoeia (EP) Reference Standard
Metolazone, European Pharmacopoeia (EP) Reference Standard