Accéder au contenu
Merck
Toutes les photos(2)

Principaux documents

MAK187

Sigma-Aldrich

Total Antioxidant Capacity Assay Kit

Sufficient for 100 Colorimetric tests

Synonyme(s) :

TAC Assay Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.84

Utilisation

sufficient for 100 colorimetric tests

Application(s)

cosmetics
environmental
food and beverages

Méthode de détection

colorimetric

Maladie(s) pertinente(s)

endocrinological disorders, diabetes; neurological disorders; cancer; cardiovascular diseases; rheumatological diseases

Température de stockage

2-8°C

Description générale

Oxidants, such as reactive oxygen species (ROS) and reactive nitrogen species (RNS), can generate free radicals that can cause severe oxidative damage to cellular lipids, membranes, proteins, and DNA.[1][2] Antioxidants can scavenge these free radicals and prevent cellular oxidative stress by enzymatic andnon-enzymatic mechanisms. Enzyme systems that function as antioxidants include catalase and peroxidase. Tocopherols, carotenes, vitamin A, and ubiquinols function as lipid-soluble antioxidants; whereas, glutathione and ascorbate are some of the water-soluble antioxidants.[3] Measurement of the total non-enzymatic antioxidant capacity (TAC) of biological samples is indicative of their ability to counteract oxidative stress-induced damage in cells. TAC is used to provide insights into the development and treatment of oxidative-stress related disorders.[4]

In the Total Antioxidant Capacity Assay Kit, either the concentration of the combination of both small molecule and protein antioxidants, or the concentration of only small molecule antioxidants can be determined. Cu2+ ion is converted to Cu+ by both small molecules and proteins. However, the use of the Protein Mask prevents Cu2+ reduction by protein, enabling the analysis of only the small molecule antioxidants. The reduced Cu+ ion chelates with a colorimetric probe, giving a broad absorbance peak at ~570 nm, which is proportional to the total antioxidant capacity. The kit gives antioxidant capacity in Trolox equivalents (ranging from 4-20 nmole/well). Trolox, a water-soluble vitamin E analog, serves as an antioxidant standard.

Application

Total antioxidant capacity assay kit has been used to determine total antioxidant capacity of leaf tissue samples.[5][6]

Adéquation

This kit is suitable for the detection of small molecule and protein antioxidants in cell and tissue lysates, media, or in biological fluids such as urine, plasma, and serum.

Principe

In the Total Antioxidant Capacity Assay Kit, either the concentration of the combination of both small molecule and protein antioxidants, or the concentration of only small molecule antioxidants can be determined. Cu2+ ion is converted to Cu+ by both small molecules and proteins. However, the use of the Protein Mask prevents Cu2+ reduction by protein, enabling the analysis of only the small molecule antioxidants. The reduced Cu+ ion chelates with a colorimetric probe, giving a broad absorbance peak at ~570 nm, which is proportional to the total antioxidant capacity. The kit gives antioxidant capacity in Trolox equivalents (ranging from 4-20 nmole/well). Trolox, a water-soluble vitamin E analog, serves as an antioxidant standard.

Composants de kit seuls

Réf. du produit
Description

  • Cu2+ Reagent

  • Assay Diluent

  • Protein Mask

  • Trolox Standard, 1 μmole

Remplacé(e)(s) par

Réf. du produit
Description
Tarif

Pictogrammes

CorrosionEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1

Code de la classe de stockage

10 - Combustible liquids


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Niclas U Lundsgaard et al.
Conservation physiology, 8(1), coaa002-coaa002 (2020-05-30)
Multiple environmental changes are thought to be contributing to the widespread decline of amphibians in montane regions, but interactions between drivers of decline are not well understood. It has been proposed previously that elevated ultraviolet-B radiation (UBVR) and low temperatures
Harjeevan Kaur et al.
Plant biotechnology journal, 18(4), 983-991 (2019-09-26)
Oilseed rape (Brassica napus) is the third largest source of vegetable oil globally. In addition to food uses, there are industrial applications that exploit the ability of the species to accumulate the very-long-chain fatty acid (VLCFA) erucic acid in its
Simon Vitt et al.
The Science of the total environment, 712, 136341-136341 (2020-01-14)
Increasing UVB radiation (UVB) reaching earth's surface following stratospheric ozone depletion is linked to serious consequences for organisms. While studies have focused on direct cytocidal and immunomodulatory effects of UVB, indirect consequences for fitness-related life-history traits are largely unexplored, although
Free radicals: properties, sources, targets, and their implication in various diseases.
Phaniendra A, et al.
Indian Journal of Clinical Biochemistry : IJCB, 30(1), 11-26 (2015)
Effects of xenobiotics on total antioxidant capacity
Ferrari C K B.
Interdisciplinary Toxicology, 5(3), 117-122 (2012)

Questions

1–4 sur 4 questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 réponse
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile ?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 réponse
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile ?

  3. What is the lower detection limit?

    1 réponse
    1. Samples should have an absorbance within the linear range of the standard curve, which is 0 – 20 nmol/well. If the absorbance falls outside this range, it is recommended to redilute and rerun the samples. The detection limit of the assay is approximately 0.1 nmol per well (or 1 µM) of Trolox.

      Utile ?

  4. Can the total antioxidative capacity kit measure cells treated with strongly colored dyes like methylene blue and detect absorbance differences at 685nm?

    1 réponse
    1. A 100 nm difference in wavelength for peak absorbance suggests that methylene blue should not interfere with the assay. Theoretically, the kit should work, but it's advisable for the customer to conduct their own tests to determine if sample dilutions are necessary.

      Utile ?

Évaluations

Aucune valeur de notation

Filtres actifs

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique