The presence of EDTA, SDS, or excess salt can affect my PCR/ sequencing reaction. The lysis buffer information is proprietary, but we can say it is free of chaotropic salts. The resins are desalting resins so EDTA, SDS, and salts are depleted.
Sélectionner une taille de conditionnement
| Taille/Référence | Disponibilité | Prix |
|---|
A propos de cet article
purified by
(Single-spin negative chromotography), (Time: 30 minutes or less)
feature
Compatible Application (Suitable for most common downstream applications, including genotyping, PCR, and NGS), Intended use (For the purification of genomic DNA from liquid blood samples), Typical/expected yield (Varies by sample. Please reference user guide for more information.)
sustainability
Sustainability features
technique(s)
DNA purification: suitable
input
blood (liquid or dried)
test parameters
: 3 min hands on time, sample volume: 200-1000 μL blood
storage temp.
2-8°C
General description
- Isolation of DNA in under an hour with minimal sample handling
- Better purity, leading to improved performance in PCR and other applications
- Significant reduction in plastic and hazardous chemical waste
Traditional silica-based, bind-wash-elute purification kits require multiple wash steps to remove impurities from the spin columns. These steps increase the risk of cross contamination, subject the DNA to centrifugation sheering forces, and introduce chaotropic salts that can carry over into the final sample, inhibiting downstream applications.
GenElute™-E kits employ size exclusion negative chromatography to separate large nucleic acid molecules from smaller protein, lipid, and ionic components in cell, tissue, blood, and other samples. Single-spin columns efficiently absorb and retain cellular debris and sample contaminants while allowing nucleic acids to pass through, reducing the number of steps and plastic materials required for purification. This novel method for high-quality purification is made possible by our innovative SmartLyse® Protease, which enables fast and efficient lysis of a wide range of sample types.
Isolate nucleic acid in a fraction of time compared to traditional silica bind-wash-elute procedures. Simply mix sample with lysis components and incubate according to kit protocol, pipette sample onto the spin column, and centrifuge directly into a collection tube. Cellular debris and contaminants remain bound in the column to be discarded, while purified DNA is ready to be used in downstream applications or stored.
Application
Features and Benefits
Other Notes
Legal Information
1 of 1
Cet article | |||
|---|---|---|---|
| description Reagents and consumables for liquid blood samples. 10, 50 or 250 purifications. | description Reagents and consumables for various cell culture sample types. 10, 50 or 250 purifications. | description Reagents and consumables for clean-up of pre-purified DNA. 10, 50 or 250 purifications. | description Reagents and consumables for various tissue sample types. 96-well plate format. |
| technique(s) DNA purification: suitable | technique(s) DNA purification: suitable | technique(s) DNA purification: suitable | technique(s) - |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. room temp | storage temp. 2-8°C |
| input blood (liquid or dried) | input cells | input - | input - |
| purified by (Time: 30 minutes or less), (Single-spin negative chromotography) | purified by (Single-spin negative chromotography), (Time: 30 minutes or less) | purified by (Single-spin negative chromotography), (Time: 3 minutes or less) | purified by (Single-spin negative chromotography) |
| sustainability Greener Alternative Product | sustainability Greener Alternative Product | sustainability Greener Alternative Product | sustainability Greener Alternative Product |
| test parameters sample volume: 200-1000 μL blood, : 3 min hands on time | test parameters : 3 min hands on time | test parameters sample volume: 90-110 μL, : 3 min hands on time | test parameters - |
Composants de kit seuls
- Erythrocyte Lysis Buffer
- Blood Lysis Buffer HY
- SmartLyse® HY Protease
- Clearing Solution HY
- 1x Tris Buffer
- Spin Columns
Mot-clé
Danger
Codes de danger
Mentions de précaution
Hazard Classifications
Aquatic Chronic 3 - Eye Dam. 1 - Flam. Liq. 2 - Met. Corr. 1 - Resp. Sens. 1
Classe de stockage
3 - Flammable liquids
Que se passe-t-il ?
WGK 3
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
-
What is the composition of the lysis buffer and clearing buffer after flowing through the resin?
1 réponse-
Utile ?
-
-
Genelute-e single spin DNA and RNA purification kits use negative chromatographty to isolate nucleic acids. Can you explain how this approach simplifies workflows?
1 réponse-
Instead of optimizing the bind, wash, and release steps in conventional silica-based spin purification preps, the technology focuses on a separation by performing a single step fractionation based on the size of the biomolecules, which results in depleted impurities.
Utile ?
-
-
Do we know how stable the purified DNA is through several freeze-thaw cycles?
1 réponse-
This will fluctuate due to sample variability (sample collection, concentration, fragment length, sequence [GC content], storage before isolation, etc.). However, the sample is buffer exchanged into a standard storage buffer that is included in the kit (1X TE).
Utile ?
-
-
Does the technology introduce any bias into the sample?
1 réponse-
GenElute™-E does not introduce biases that some “bind-wash-elute” technologies can add because the technology separates by size, rather than by what binds and what is released.
Utile ?
-