Accéder au contenu
Merck
Toutes les photos(1)

Documents

C-43080

Sigma-Aldrich

NCCD Reagent

2 ml

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352207
Nomenclature NACRES :
NA.71

Forme

aqueous solution

Technique(s)

cell culture | mammalian: suitable

Conditions d'expédition

dry ice

Température de stockage

−20°C

Description générale

NCCD Reagent

Application

NCCD Reagent is intended exclusively for use in combination with the PromoCell Primary Cancer Cell Culture Medium D-ACF (C-28081). It allows for the culture vessel surface pre-treatment which is critical for the functionality of the Primary Cancer Cell Culture System.

Qualité

All lots of PromoCell NCCD Reagent are subjected to comprehensive quality control tests. Each lot is routinely tested for functionality using a human cancer cell line in conjunction with the Primary Cancer Culture Medium D-ACF. In addition, all lots of media have been tested for the absence of microbial contaminants (fungi, bacteria, mycoplasma).

Notes préparatoires

The NCCD Reagent is provided as a 20x stock and must be diluted to a working concentration before use. One 2 ml vial of NCCD Reagent yields 40 ml of ready-to-use working solution sufficient to treat 400 cm2 of culture surface, e.g. seven complete 6-well plates.Dilute the thawed NCCD Reagent stock solution 1:20 with PBS w/o Ca2+/Mg2+. Use 100 uL per cm2 of culture surface to treat the tissue culture vessel with the diluted NCCD Reagent and leave the closed vessel for at least 1 hour at RT. Make sure that the NCCD covers the entire vessel surface. Aspirate the NCCD solution just before seeding the cells.

Stockage et stabilité

Store at -20°C immediately after arrival. If stored properly, the product is stable until the expiry date stated on the label. Unless used immediately, the sealed vessel containing the NCCD Reagent may be stored for up to 3 months at 2 to 8°C for later use. Diluted NCCD Reagent solution may be stored for up to 4 weeks at 2 to 8°C. Protect from light.

Procédure de repiquage

Click here for more information.

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

nwg


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Contenu apparenté

The PromoCell Primary Cancer Culture System allows selective isolation of malignant cancer cells from tumor associated stromal cells in patient derived xenographs (PDX models) and tumor samples.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique