The column has fixed polypropylene end caps, polyethylene bed supports, and Luer-Lock inlet and outlet fittings. The column outlet and reservoir top are permanently attached, while the reservoir cap is threaded. For the 0.7 cm i.d., there is no flow adapter, and a funnel can be used to pack the column after removing the threaded reservoir cap.
C3669
Colonnes de chromatographie liquide
Luer Lock, Non-jacketed, bed volume 4 mL, I.D. × L 0.7 cm × 10 cm
Sélectionner une taille de conditionnement
Sélectionner une taille de conditionnement
About This Item
Produits recommandés
Qualité
for chromatography
Technique(s)
LPLC: suitable
D.I. × L
0.7 cm × 10 cm
Volume du lit
4 mL
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
A - Luer-Lock, Non Jacketed: Fixed polypropylene end caps, polyethylene bed supports, Luer-Lock inlet and outlet fittings.
B - Luer-Lock, Jacketed: Same as A (above), with a borosilicate glass jacket surrounding the column body for temperature control.
C - Open-ended: Fixed polypropylene ends (outside of tube only), without jacket or end fittings. Requires 2 flow adapters.
D - PTFE, non-jacketed: Threaded ends, removable PTFE fittings with shielded O-ring seals, 20 μm polyethylene bed supports, and 1/4-28 threaded tubing connections. Solvents contact only PTFE and borosilicate glass.
E - PTFE, jacketed: Same as D (above), with an acrylic jacket surrounding the column body for temperature control.
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
-
Can the top of this column be unscrewed for packing purposes? Also, do you have a detailed image of this column?
1 réponse-
Utile ?
-
-
Questo tipo di colonna con codice C-3669 è compatibile con solventi organici come esano, diclorometano o acetato di etile?
1 réponse-
This column has not been tested with these solvents. It will be damaged by dichloromethane and ethyl acetate. Hexane may cause swelling and leakage.
Utile ?
-