81506
Poly(methyl methacrylate) standard ReadyCal set Mp ~800-2′200′000
for GPC
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Qualité
for GPC
Durée de conservation
limited shelf life, expiry date on the label
Technique(s)
gel permeation chromatography (GPC): suitable
Format
neat
Température de stockage
2-8°C
Application
- PMMA molecular weight calibration in medical device manufacturing: High molecular weight PMMA is used in the stereolithography fabrication of medical devices, ensuring precise control over polymer properties for innovative therapeutic applications (Drizdal et al., 2012).
- Biopolymer size characterization for protein analysis: PMMA standards are essential in the development of miniaturized gel electrophoresis devices, facilitating the analysis of proteins which is pivotal in pharmaceutical research and diagnostic applications (Demianova et al., 2008).
Conditionnement
1 set contains 30 vials for 10 complete calibrations
Composants
ReadyCal Standards are polymer cocktails pre-weighed into autosampler vials for the convenient calibration of GPC/SEC/GFC systems.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
Code de la classe de stockage
11 - Combustible Solids
Classe de danger pour l'eau (WGK)
WGK 3
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Équipement de protection individuelle
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
mSphere, 5(5) (2020-09-11)
The major surface lipophosphoglycan (LPG) of Leishmania parasites is critical to vector competence in restrictive sand fly vectors in mediating Leishmania attachment to the midgut epithelium, considered essential to parasite survival and development. However, the relevance of LPG for sand
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique