Here are the troubleshooting steps for the dialysis set-up and nitrogen escape from the top lead seal:
1) Before starting the diafiltration, customers should run gas pressure directly to the stirred cell for 5-10 seconds with the selector valve in “gas” mode.
2) Petroleum jelly will likely be required to completely seal the top gasket of the stirred cell.
UFSC05001
Cellule à agitation Amicon® 50 ml
This Amicon stirred cell model provides high flow rates with solutions up to 10% macrosolute concentration. Capable of rapid concentration, or salt removal followed by concentration in the same unit.
Synonyme(s) :
Cellule à agitation
About This Item
Produits recommandés
Matériaux
316 stainless steel ring(s) (stir bar retaining)
316 stainless steel washer
Nylon connections (Luer on filtrate tubing)
Tygon® tubing (filtrate; E-3603)
polyacetal base
polyacetal support (for stir bar)
polyethylene tubing (pressure)
polysulfone body
polysulfone cap
polysulfone holder (for membrane)
polysulfone stir bar(s)
silicone O-ring
silicone gasket
Niveau de qualité
Gamme de produits
Amicon®
Fabricant/nom de marque
Amicon®
Paramètres
50 mL process volume
Technique(s)
protein clean-up: suitable (desalting)
protein purification: suitable (concentration)
Hauteur
11.7 cm (4.6 in.)
Diam. du filtre
44.5 mm
Surface de filtration
13.4 cm2
Conditions d'expédition
ambient
Application
Principe
Liaison
Informations légales
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
-
How can I troubleshoot the issue with ufsc05001 where, during the process of diafiltration to push liquid into the stirred cell, the liquid is added too fast and overflows?
1 réponse-
Utile ?
-
-
Is the membrane holder for the Amicon Stirred Cell UFSC05001 sold as a replacement part?
1 réponse-
No, the membrane holder component of the UFSC Amicon Stirred Cells is not sold separately.