Sélectionner une taille de conditionnement
| Taille/Référence | Disponibilité | Prix |
|---|
A propos de cet article
Nom du produit
Système de détection de protéines SNAP id® 2.0 Mini (7,5 x 8,4 cm), Developed to meet the needs of our Western blotting customers, the SNAP i.d. 2.0 system produces blots of a very high quality. Unique vacuum-driven technology & a built-in flow distributor actively drive reagents through the membrane..
manufacturer/tradename
SNAP id®
technique(s)
western blot: suitable
compatibility
for use with Commercially available blocking reagents, for use with Luminata Western HRP Substrates, for use with Nitrocellulose, for use with PVDF (Immobilon membranes), for use with blØk<TMSYMBOL></TMSYMBOL>-CH Buffer (cat. no. WBAVDCH01), for use with blØk<TMSYMBOL></TMSYMBOL>-FL Buffer (cat. no. WBAVDFL01), for use with blØk<TMSYMBOL></TMSYMBOL>-PO Buffer (cat. no. WBAVDP001), for use with commercially available detection reagents
detection method
chemiluminescent, colorimetric, fluorometric
shipped in
ambient
storage temp.
room temp
General description
Application
Features and Benefits
- Peut traiter jusqu'à quatre membranes à la fois sur une base sous vide à deux faces contrôlées individuellement
- Comporte trois tailles de cadre de support de membrane amovibles : MultiBlot, Mini et Midi, pour accueillir différentes tailles de membrane
- Supports de membrane jetables adaptés aux cadres MultiBlot, Mini et Midi
- L'espaceur de membrane, nécessaire avec le système SNAP id de première génération, est maintenant intégré au nouveau support de membrane
- Options de traitement de membrane prolongé et hors ligne : les cadres possèdent un couvercle et peuvent être retirés de la base pour une incubation prolongée (d'une heure à toute une nuit), une incubation dans un agitateur, ou une incubation à 4 °C
- Comme les cadres peuvent être empilés, il est possible de traiter plusieurs membranes en même temps, pour une immunodétection en 30 minutes avec un signal uniforme sur toute la surface des membranes
- Récupération des anticorps supérieure à 80 % grâce aux plateaux de collecte d'anticorps SNAP id 2.0
- Compatible avec les membranes en nitrocellulose et en poly(fluorure de vinylidène) (PVDF)
- Fonctionne avec la plupart des tampons de blocage et des méthodologies de visualisation (par ex. chimiluminescence, fluorescence ou colorimétrie)
Packaging
Other Notes
Legal Information
1 of 1
Cet article | |||
|---|---|---|---|
| description Developed to meet the needs of our Western blotting customers, the SNAP i.d. 2.0 system produces blots of a very high quality. Unique vacuum-driven technology & a built-in flow distributor actively drive reagents through the membrane.. | description Developed to meet the needs of our Western blotting customers, the SNAP i.d. 2.0 system produces blots of a very high quality. Unique vacuum-driven technology & a built-in flow distributor actively drive reagents through the membrane. | description Snap i.d. 2.0 Antibody Collection Tray. | description The new Midi Blot Holders ensure the membrane is horizontal allowing uniform Antibody distribution. The flat profile alows for compact space allocation for storage, shipping & waste management. |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| storage temp. room temp | storage temp. room temp | storage temp. room temp | storage temp. - |
| detection method fluorometric, colorimetric, chemiluminescent | detection method chemiluminescent, colorimetric, fluorometric | detection method colorimetric, chemiluminescent, fluorometric | detection method fluorometric, chemiluminescent, colorimetric |
| manufacturer/tradename SNAP id® | manufacturer/tradename SNAP id® | manufacturer/tradename SNAP id® | manufacturer/tradename SNAP id® |
| compatibility for use with PVDF (Immobilon membranes), for use with blØk<TMSYMBOL></TMSYMBOL>-CH Buffer (cat. no. WBAVDCH01), for use with Commercially available blocking reagents, for use with Nitrocellulose, for use with Luminata Western HRP Substrates, for use with blØk<TMSYMBOL></TMSYMBOL>-PO Buffer (cat. no. WBAVDP001), for use with commercially available detection reagents, for use with blØk<TMSYMBOL></TMSYMBOL>-FL Buffer (cat. no. WBAVDFL01) | compatibility for use with Luminata Western HRP Substrates, for use with blØk<TMSYMBOL></TMSYMBOL>-PO Buffer (cat. no. WBAVDP001), for use with commercially available detection reagents, for use with blØk<TMSYMBOL></TMSYMBOL>-FL Buffer (cat. no. WBAVDFL01), for use with Commercially available blocking reagents, for use with Nitrocellulose, for use with PVDF (Immobilon membranes), for use with blØk<TMSYMBOL></TMSYMBOL>-CH Buffer (cat. no. WBAVDCH01) | compatibility for use with Commercially available blocking reagents, for use with blØk<TMSYMBOL></TMSYMBOL>-PO Buffer (cat. no. WBAVDP001), for use with Luminata Western HRP Substrates, for use with PVDF (Immobilon membranes), for use with commercially available detection reagents, for use with Nitrocellulose, for use with blØk<TMSYMBOL></TMSYMBOL>-CH Buffer (cat. no. WBAVDCH01), for use with blØk<TMSYMBOL></TMSYMBOL>-FL Buffer (cat. no. WBAVDFL01) | compatibility for use with blØk<TMSYMBOL></TMSYMBOL>-CH Buffer (cat. no. WBAVDCH01), for use with commercially available detection reagents, for use with Commercially available blocking reagents, for use with blØk<TMSYMBOL></TMSYMBOL>-FL Buffer (cat. no. WBAVDFL01), for use with Luminata Western HRP Substrates, for use with PVDF (Immobilon membranes), for use with blØk<TMSYMBOL></TMSYMBOL>-PO Buffer (cat. no. WBAVDP001), for use with Nitrocellulose |
| technique(s) western blot: suitable | technique(s) western blot: suitable | technique(s) western blot: suitable | technique(s) western blot: suitable |
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.