700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)
S200B10RE
Flacon de réception Millipore® Stericup®
capacity 1000 mL, sterile; irradiated, pack of 12 ea
Synonyme(s) :
Flacon de réception Stericup Quick Release, SC00B10RE
About This Item
Produits recommandés
Matériaux
polystyrene bottle
Niveau de qualité
Stérilité
sterile; irradiated
Gamme de produits
Stericup®
Conditionnement
pack of 12 ea
Paramètres
45 °C max. temp.
Description
2.4 mL (hold-up volume)
Hauteur
183 mm
Capacité
1000 mL
Diamètre
45 mm
Raccords
45 mm inlet thread(s)
outlet bottle top (Universal)
Compatibilité
for use with Steritop Filter Units
Conditions d'expédition
ambient
Description générale
Les flacons de réception Stericup® sont équipés d'un bouchon à fermeture par clic particulièrement fiable qui assure une prise en main sûre aussi bien en conditions humides que sèches. Une butée tactile confirme que le bouchon du flacon de réception est parfaitement fermé, et une zone d'écriture dépolie sur le flacon de réception permet d'étiqueter les solutions de façon pratique.
Ce flacon de réception Stericup® avec une ouverture de 45 mm offre une capacité de 1 000 ml.
Application
- Milieux de culture cellulaire +/- additifs
- Tampons
- Solutions biologiques
Caractéristiques et avantages
- Le bouchon à fermeture par clic est muni d'une collerette et est modifié pour assurer une prise en main sûre aussi bien en conditions humides que sèches—et une butée tactile confirme la fermeture sécurisée. Ne vous inquiétez pas du risque de déversement ou de contamination du contenu stérilisé.
- Une large zone d'écriture dépolie sur le flacon de réception et la couleur plus claire du bouchon permettent un étiquetage clair pour améliorer la lisibilité et réduire les bavures illisibles.
- Le bouchon à fermeture par clic repose sur le côté pour éviter tout risque de contamination.
- Les flacons de réception sont empilables pour gagner de l'espace de stockage.
Informations légales
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
-
What is the maximum vacuum pressure for filtration?
1 réponse-
Utile ?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 réponse-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Utile ?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 réponse-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Utile ?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 réponse-
No, all Stericup® and Steritop® devices are Research Use Only.
Utile ?
-
-
Are Stericup® and Steritop® filters GMP-certified?
1 réponse-
No, Stericup® and Steritop® devices are not GMP-approved.
Utile ?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 réponse-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Utile ?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 réponse-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
Utile ?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 réponse-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)Utile ?
-
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 réponse-
You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
Utile ?
-
-
Which type of pump should be used with Stericup® and Steritop® vacuum filters?
Which type of pump should be used with Stericup® and Steritop® vacuum filters?
1 réponse-
We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560
Utile ?
-
Filtres actifs
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique