Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

L70DET6S1

Millipore

Filtre à disques lenticulaires Millistak+®

DE70, cellulose, filtration area 3.47 m2, hydrophilic

Synonyme(s) :

Millistak+ Lenticular Disc Filters, DE70 media series, 16 in. diameter, 16-cell, silicone seal

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806
eCl@ss :
32031690

Matériaux

cellulose
filter aid (inorganic)
polypropylene
silicone seal

Niveau de qualité

Description

For clarification of serum, plasma, vaccines, cell culture or other fluids.

Caractéristiques

hydrophilic

Fabricant/nom de marque

Millistak+®

Paramètres

0.03 bar max. differential pressure (0.5 psid) (Reverse)
0.2 bar max. inlet pressure (3 psi) at 123 °C
0.21 bar max. differential pressure (3 psid) at 123 °C (Forward)
1 bar max. inlet pressure (15 psi) at 80 °C
1.03 bar max. differential pressure (15 psid) at 80 °C (Forward)
2.07 bar max. differential pressure (30 psid) at 25 °C (Forward)
2.1 bar max. inlet pressure (30 psi) at 25 °C

Hauteur

27.6 cm (10.88 in.)

Diamètre

40.64 cm (16 in.)

Surface de filtration

3.47 m2

Impuretés

<0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

non-volatile residue (NVR)

3.93-6.43 mg/m2 (gravimetric analysis test)

Résidus de Carbone Oxydable Total (COT)

753-1,567 ppb (gravimetric analysis test)
753-1567 ppb

Entrée

sample type liquid

Conductivité

9-12 μmho per cm at 25 °C (product water)

Grade du filtre

DE70

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Device Configuration: Stack Disk
Stack Design: 16 in. diameter, 16-cell

Application

For clarification of serum, plasma, vaccines, cell culture or other fluids.

Caractéristiques

Filter Grade: DE70

Notes préparatoires

Sanitization Protocol
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Sterilization Method
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C

Remarque sur l'analyse

Gravimetric Extractables: Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 50 L/m2 of media surface area
Product Water Conductivity at 25°C: after a pure water flush of 5 liters per ft2 (50 L/m2) of media surface area per autoclaved (1 cycle of 30 minutes at 123 °C) 12" 16-stack device
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Total Organic Carbon (TOC) Residue: ppb post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 5 liters per ft2 (50 L/m2) of media surface area

Informations légales

MILLISTAK+ is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

Health hazard

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

STOT RE 1 Inhalation

Organes cibles

Lungs

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de danger pour l'eau (WGK)

WGK 3


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique