KHGES10HH1
Millipore Express® SHC, Capsule Opticap® XL
Opticap® XL 10, sterile, inlet connection diam. 9/16 in., pore size 0.5/0.2 μm, cartridge nominal length 10 in. (25 cm)
Synonyme(s) :
Opticap Sterile XL 10 Millipore Express SHC 0.5/0.2 μm 9/16 in. HB/HB
About This Item
Produits recommandés
Matériaux
polyester support
polyethersulfone membrane
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Niveau de qualité
Conformité réglementaire
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Stérilité
irradiated
sterile
Gamme de produits
Opticap® XL 10
Caractéristiques
hydrophilic
Fabricant/nom de marque
Millipore Express®
Paramètres
≤31.2 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C ( in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
Technique(s)
sterile filtration: suitable
Longueur
33.5 cm (13.2 in.)
Longueur nominale des cartouches
10 in. (25 cm)
Diamètre
10.7 cm (4.2 in.)
Surface de filtration
0.54 m2
Diam. du raccord d'entrée
9/16 in.
Largeur, de l'entrée à la sortie
33.5 cm (13.2 in.)
Diam. du raccord de sortie
9/16 in.
Impuretés
≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
Point de bulle
≥4000 mbar (58 psig), air with water at 23 °C
Raccords
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Description générale
Conditionnement
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Notes préparatoires
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 21 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informations légales
Clause de non-responsabilité
Not finding the right product?
Try our Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
Key aspects of single-use assembly qualification including quality by design (QbD), quality risk management (QRM) and operator handling and training.
Before adoption of single-use technologies in biomanufacturing, manufacturers must assess the risk to the drug product from potential leachables. This article highlights a general approach based on the United States Pharmacopeia (USP).
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique