Accéder au contenu
Merck
Toutes les photos(2)

Documents

4.80364

Supelco

Sulfuric acid solution

c(H₂SO₄) = 2.5 mol/l (5 N), ready-to-use volumetric solution for titration, Titriplex®

Synonyme(s) :

Sulfuric acid solution

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
H2SO4
Numéro CAS:
Poids moléculaire :
98.08
Numéro Beilstein :
2037554
Numéro MDL:
Code UNSPSC :
12352301
Nomenclature NACRES :
NA.21

product name

Acide sulfurique solution, c(H2SO4) = 2.5 mol/l (5 N), Titripur®

Niveau de qualité

Gamme de produits

Titripur®

Forme

liquid

Qualité

Analyzed in our ISO 17025 accredited QC lab

Capacité de réaction

reaction type: Acid-base reactions

Concentration

2.5 M

Technique(s)

titration: suitable

pH

1 (20 °C in H2O)

Densité

1.15 g/cm3 at 20 °C

Température de stockage

15-25°C

Chaîne SMILES 

OS(O)(=O)=O

InChI

1S/H2O4S/c1-5(2,3)4/h(H2,1,2,3,4)

Clé InChI

QAOWNCQODCNURD-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application


  • Stability and Structure of Potentially Atmospherically Relevant Glycine Ammonium Bisulfate Clusters: This research examines the complex interactions and stability of atmospheric aerosols involving sulfuric acid, providing insights valuable for environmental scientists and chemists studying atmospheric chemistry and pollution mitigation strategies (Hariharan et al., 2024).

  • Nanostructured Niobium and Titanium Carbonitrides as Electrocatalyst Supports: Discusses the role of sulfuric acid in synthesizing nanostructured materials for energy applications, relevant for material scientists and researchers in renewable energy technologies (McLeod et al., 2024).

  • Synthesis and characterization of hydroxyapatite nanoparticles from calcium hydroxide fouled with gases evolved from the smokestack of the glass industry: Highlights the utility of sulfuric acid in the synthesis of nanoparticles for industrial applications, crucial for researchers in materials science and industrial manufacturing (Abdelmoaty and Mousa, 2024).

  • Enabling nucleophilic reactivity in molecular calcium fluoride complexes: This study features sulfuric acid in the activation and stabilization of reactive intermediates in chemical syntheses, pivotal for chemists and pharmaceutical researchers engaged in synthetic chemistry (Struijs et al., 2024).

  • Nucleophilic hydrolysis enables HF-etched MXene kilofarad specific capacitance and excellent rate performance: Demonstrates the application of sulfuric acid in enhancing the performance of electrochemical storage devices, relevant for material scientists working on advanced battery technologies (Xu et al., 2024).

Caractéristiques et avantages

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Conditionnement

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Remarque sur l'analyse

Form liquid
Amount-of-substance concentration 2.4875 - 2.5125 mol/L
Measurement uncertainty ± 0.0075 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Informations légales

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Pictogrammes

Corrosion

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Code de la classe de stockage

8B - Non-combustible, corrosive hazardous materials

Classe de danger pour l'eau (WGK)

WGK 1


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique