Accéder au contenu
Merck
Toutes les photos(1)

Documents

1.14842

Supelco

Phosphate Test, photometric

photometric, 0.5-30.0 mg/L (PO4-P), 1.5-92.0 mg/L (PO43-), 1.1-68.7 mg/L (P2O5), Spectroquant®

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41116116
Nomenclature NACRES :
NA.24

product name

Phosphate Test, photometric, 0.5-30.0 mg/L (PO4-P), 1.5-92.0 mg/L (PO43-), 1.1-68.7 mg/L (P2O5), Spectroquant®

Gamme de produits

Spectroquant®

Niveau de qualité

Utilisation

sufficient for 400 tests

Analyte(s) spécifique(s)

phosphate

Plage de mesure

0.5-30.0 mg/L (PO4-P)
1.1-68.7 mg/L (P2O5)
1.5-92.0 mg/L (PO43-)

Technique(s)

photometry: suitable

Compatibilité

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600

Méthode de détection

photometric (Vanadato-molybdate)

Température de stockage

15-25°C

Description générale

(o-phosphate) Method: photometric, VM 0.5 - 30.0 mg/l PO₄-P 1.5 - 92.0 mg/l PO₄³⁻ 1.1 - 68.7 mg/l P₂O₅ Spectroquant®
The method is analogous to APHA 4500-P C.
This Spectroquant® Reagent Test is especially designed for the analysis of processes water. In order to avoid long downtimes and intensive maintenance costs of processes water systems a precisely adjusted level of phosphate in the water is paramount to ensure water pipes are protected and corrosion is limited to a minimum.
The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet .
All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Application


  • Environmental Monitoring: Phosphate tests are extensively used in environmental monitoring to assess the levels of phosphate in water bodies. These tests help in evaluating the impact of agricultural runoff, industrial discharge, and wastewater treatment on water quality. Recent studies have focused on using selective colorimetric nano-sensing solutions to determine phosphate ions in drinking water samples, highlighting their importance in ensuring safe and clean water supplies (Salem and Draz, International Journal of Environmental Analytical Chemistry, 2020).

Informations légales

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

Corrosion

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Code de la classe de stockage

8B - Non-combustible, corrosive hazardous materials

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique