Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

749192

Sigma-Aldrich

Poly(styrene-block-methyl methacrylate)

average Mn 104,000, block ratio of 1:1

Synonyme(s) :

PS-block-PMMA, PS-PMMA

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Code UNSPSC :
12162002

Forme

solid

Poids mol.

average Mn 104,000
average Mn 52,000 (PMMA)
average Mn 52,000 (polystyrene)

Température de transition

Tm 345-350 °C

Mw/Mn

<1.2

InChI

1S/C8H8.C5H8O2/c1-2-8-6-4-3-5-7-8;1-4(2)5(6)7-3/h2-7H,1H2;1H2,2-3H3

Clé InChI

ADFPJHOAARPYLP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

57 kDa PS; 25 kDa PMMA; m ~494; n ~520
PS Mn = 57 ± 6 kg/mol
PMMA Mn = 25 ± 3 kg/mol
PDI of the overall block copolymer <1.2
PS molecular weight verified by SEC (taking an aliquot from the reaction mixture) and the PMMA molecular weight by NMR spectroscopy. The overall block copolymer molecular weight distribution would be determined by SEC.

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Conseils de prudence

Classification des risques

Eye Irrit. 2

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

MN: Surgical LPN files product liability suit: cement Mfgr.'s failure to warn of health hazard.
Nursing law's Regan report, 42(8), 3-3 (2004-08-11)
G N Thomopoulos et al.
The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society, 31(7), 871-878 (1983-07-01)
The high iron diamine (HID) method for detection of sulfated complex carbohydrate has been applied directly on thin sections of variably fixed tissues embedded in epoxy and nonepoxy resins. Results with postembedment HID staining in mouse intestinal epithelium are compared
M E Forsythe et al.
Journal of orthopaedic surgery (Hong Kong), 14(1), 38-42 (2006-04-07)
To compare the pharmacokinetic profile of tobramycin in blood, urine, and at the operative site following the use of Simplex-tobramycin bone cement in primary total hip replacement between patients with and without renal dysfunction. Six patients with renal dysfunction underwent
N S Dar-Odeh et al.
Journal of oral rehabilitation, 24(10), 755-760 (1997-12-31)
The aim of this study was to compare some of the physical properties of a heat-cured, a self-cured and a visible light-cured acrylic resin, and to evaluate the suitability of visible light-cured resin as a repair material for dentures made
Novel fabrication of 2D and 3D inverted opals and their application.
Jae Ah Lee et al.
Small (Weinheim an der Bergstrasse, Germany), 7(18), 2581-2586 (2011-08-03)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique