Saltar al contenido
Merck

KCQS00

Sigma-Aldrich

KiCqStart® SYBR® Green qPCR ReadyMix

For Bio-Rad, Cepheid, Eppendorf, Illumina, Corbett, and Roche systems

Sinónimos:

qPCR master mix, sybr green qPCR

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41106300
NACRES:
NA.55

formulario

liquid

uso

sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions

Características

dNTPs included
hotstart

condiciones de almacenamiento

protect from light

técnicas

qPCR: suitable

color

colorless

entrada

purified DNA

compatibilidad

for use with Bio-Rad CFX384
for use with Bio-Rad CFX96
for use with Bio-Rad MJ Chromo4
for use with Bio-Rad MJ Opticon 2
for use with Bio-Rad MJ Opticon Cepheid SmartCycler
for use with Bio-Rad MiniOpticon
for use with Bio-Rad MyiQ
for use with Eppendorf® Mastercycler ep realplex2 s
for use with Eppendorf® Mastercycler ep realplex
for use with Illumina Eco qPCR
for use with Qiagen Corbett Rotor-Gene 3000
for use with Qiagen Corbett Rotor-Gene 6000
for use with Qiagen Corbett Rotor-Gene Q
for use with Roche LightCycler 480

método de detección

SYBR® Green

Condiciones de envío

dry ice

temp. de almacenamiento

−20°C

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

KiCqStart SYBR Green qPCR ReadyMix es una mezcla maestra lista para usar concentrado X2 que contiene todos los componentes, excepto los cebadores y la plantilla, para la PCR cuantitativa (qPCR) en tiempo real Esta combinación única de tampón patentado, estabilizadores y ADN polimerasa Taq de inicio en caliente proporciona la eficiencia, sensibilidad y especificidad máximas de la PCR y una señal fluorescente robusta cuando se utilizan protocolos de ciclado rápidos o convencionales con SYBR Green qPCR.

Es crucial una amplificación muy específica para conseguir una qPCR satisfactoria con tecnología de colorante SYBR Green I porque este colorante se une a, y detecta, cualquier dsDNA generado durante la amplificación. La ADN polimerasa Taq de inicio en caliente es inactivada por anticuerpo antes de la etapa inicial de desnaturalización de la PCR.

Aplicación

KiCqStart® SYBR® Green qPCR ReadyMix has been used to perform quantitative real-time PCR (qPCR) for the amplification and quantification of genomic DNA extracted from human gut bacterium Prevotella copri.
Aplicaciones de la PCR:
  • Expresión génica
  • Cuantificación del ADN
  • CHiP

Características y beneficios

  • Resultados del análisis en tan sólo 33 minutos
  • Resultados de la PCR en tiempo real muy eficaces y sensibles
  • Se requiere poca o ninguna optimización

Componentes

2X reaction buffer containing optimized concentrations of MgCl2, dNTPs (dATP, dCTP, dGTP, dTTP), KiCqStart Taq DNA Polymerase, SYBR Green dye, and stabilizers

packaging:
250 reactions* = 2 X 1.25 mL tubes
1250 reactions* = 10 X 1.25 mL tubes
5000 reactions* = 1 X 50 mL tube
*number of reactions based on a 20uL volume

Otras notas

Condiciones de conservación:
La mezcla KiCqStart SYBR Green qPCR ReadyMix es estable durante 1 año cuando se conserva en un refrigerador a una temperatura constante de -20°C, protegida de la luz. Para su conveniencia, puede conservarse sin congelar entre +2 y +8°C durante un máximo de 6 meses. Después de descongelar, mezcle bien antes de usar. No se recomienda congelar y descongelar repetidamente el producto. Sin embargo, se demostró que el producto no perdía rendimiento después de 20 ciclos de congelación-descongelación o 2 meses a +20°C.
Instrument Compatibility:
Different real-time PCR systems employ different strategies for normalization of fluorescent signals and correction of well-to-well optical variations. It is critical to match the appropriate qPCR reagent to your specific instrument. KiCqStart SYBR Green qPCR ReadyMix does not contain an internal reference dye. Compatible instruments include:
  • Bio-Rad® CFX384
  • Bio-Rad CFX96
  • Bio-Rad MiniOpticon
  • Bio-Rad/MJ Chromo4
  • Bio-Rad/MJ Opticon 2
  • Bio-Rad/MJ Opticon
  • Cepheid SmartCycler®
  • Eppendorf Mastercycler® ep realplex
  • Eppendorf Mastercycler ep realplex2 s
  • Illumina Eco qPCR
  • Qiagen/Corbett Rotor-Gene® 3000
  • Qiagen/Corbett Rotor-Gene 6000
  • Qiagen/Corbett Rotor-Gene Q
  • Roche LightCycler® 480

Información legal

Bio-Rad is a registered trademark of Bio-Rad Laboratories, Inc.
CFX384 is a trademark of Bio-Rad Laboratories, Inc.
CFX96 is a trademark of Bio-Rad Laboratories, Inc.
Chromo4 is a trademark of Bio-Rad Laboratories, Inc.
Eppendorf is a registered trademark of Eppendorf AG
KiCqStart is a registered trademark of QIAGEN Beverly Inc.
LightCycler is a registered trademark of Roche
Mastercycler is a registered trademark of Eppendorf AG
MiniOpticon is a trademark of Bio-Rad Laboratories, Inc.
Opticon is a trademark of Bio-Rad Laboratories, Inc.
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Rotor-Gene is a registered trademark of Qiagen GmbH
SYBR is a registered trademark of Life Technologies
SmartCycler is a registered trademark of Cepheid, Inc.

Código de clase de almacenamiento

12 - Non Combustible Liquids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Tsion Zewdu Minas et al.
Oncotarget, 8(21), 34141-34163 (2016-05-19)
Ewing sarcoma (ES) involves a tumor-specific chromosomal translocation that produces the EWS-FLI1 protein, which is required for the growth of ES cells both in vitro and in vivo. However, an EWS-FLI1-driven transgenic mouse model is not currently available. Here, we
Muthappa Senthil-Kumar et al.
Nature protocols, 9(7), 1549-1562 (2014-06-06)
Tobacco rattle virus (TRV)-based virus-induced gene silencing (VIGS) is widely used in various plant species to downregulate the expression of a target plant gene. TRV is a bipartite, positive-strand RNA virus with the TRV1 and TRV2 genomes. To induce post-transcriptional
Phebe Verbrugghe et al.
BMC microbiology, 21(1), 23-23 (2021-01-13)
Since its discovery in 2007, the importance of the human gut bacterium Prevotella copri (P. copri) has been widely recognized with its links to diet and health status and potential as next generation probiotic. Therefore, precise, convenient and cost-effective diagnostic
NLRX1 Enhances Glutamate Uptake and Inhibits Glutamate Release by Astrocytes
Mahmoud S, et al.
Cells, 8(5), 400-400 (2019)
YK-4-279 effectively antagonizes EWS-FLI1 induced leukemia in a transgenic mouse model.
Minas TZ
Oncotarget, 6(35), 37678-37694 (2015)

Artículos

After a traditional PCR has been completed, the PCR/qPCR data analysis is conducted by resolution through an agarose gel or, more recently, through a capillary.

PCR assay guide navigates you through primer validation and other assay optimization factors to ensure high sensitivity and specificity for optimum DNA/ RNA quantification.

Real-time polymerase chain reaction allows researchers to estimate the quantity of starting material in a sample. It has a much wider dynamic range of analysis than conventional PCR

Protocolos

Quantitative PCR protocol using SYBR Green reagents. Procedure supports most qPCR instruments.

Optimization of qPCR conditions is important for the development of a robust assay. The two main approaches are optimization of primer concentration and/or annealing temperatures.

Analysis of gene expression data requires a stable reference or loading control. This reference is usually one or more reference genes.

SYBR Green I dye in qPCR measures target quantity, adaptable to specific needs with a standard protocol.

Ver todo

Contenido relacionado

SYBR® Green I, a commonly used fluorescent DNA binding dye, binds all double-stranded DNA and detection is monitored by measuring the increase in fluorescence throughout the cycle. Explore our LuminoCt® and KiCqStart® products for Fast qPCR or JumpStart™ reagents for conventional qPCR

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico