MCE50054H1
Filtro de profundidad Millistak+® Pod
CE50, cellulose, filtration area 0.054 m2, hydrophilic
Sinónimos:
Millistak+ Pod Depth Filter, CE50 media series, 0.054 m2 surface area, 1/4 in. Hose Barb connection
About This Item
Productos recomendados
Materiales
cellulose
glass fiber-reinforced polypropylene
Nivel de calidad
descripción
For clarification of serum, plasma, vaccines, cell culture or other fluids.
Características
hydrophilic
fabricante / nombre comercial
Millistak+®
Parámetros
1 bar max. differential pressure (15 psid) at 80 °C (Forward)
1 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psid) at 25 °C (Forward)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse)
3.5 bar max. inlet pressure (50 psi) at 25 °C
Altura
14 cm (5.3 in.)
Longitud
22 cm (8.5 in.)
filtración área
0.054 m2
impurezas
<0.25 EU/mL (LAL test, Aqueous extraction)
entrada
sample type liquid
conductividad
1.52 – 1.94 μS/cm
grado de filtro
CE50
Condiciones de envío
ambient
Descripción general
This CE50 media series delivers optimal performance through a gradient density matri, ideal for primary (coarse) clarification applications. Millistak+® Pod filters are available in three distinct series of media grades in order to meet your specific needs - DE, CE and HC.
The Millistak+® Pod system is ideal for a wide variety of primary and secondary clarification applications, including cell cultures, yeast and E. coli lysates post centrifuge, E. coli refolds, media, vaccines, plasma proteins and sera.
Easy to Use
With the compact, modular design of our Millistak+® new Pod system, you can increase productivity and shorten cycle times.
Installation and setup of the Pod system is simple and straightforward. The unique design of the disposable adapters and disposable manifolds makes it easy to connect the Pod filters to rest of the unit operations in the process. The self-contained and disposable nature of the system protects operators from exposure to biohazards and eliminates maintenance as well as cleaning validation requirements.
Aplicación
Características y beneficios
- Low hold-up volume for greater product yield
- Broad range of media types offered in single and multilayer products
- Flexible, modular format offers scalability from 5 to 12,000 liters or more
- Patented disposable design eliminates need for housing, CIP or cleaning validation
- Self-contained Pod filters protect operators from exposure to biohazards
- Robust construction is easy to use and set up
- Smaller footprint facilitates use in tight spaces
Especificaciones
Nota de preparación
1 autoclave cycle of 60 min @ 123 ºC
Información legal
Código de clase de almacenamiento
10-13 - German Storage Class 10 to 13
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico