Saltar al contenido
Merck
Todas las fotos(1)

Documentos

KWL6A10HH1

Millipore

Milligard® LPB 0,5 0.2 µm nominal, cápsula Opticap® XL

nominal pore size 0.5 μm, Opticap® XL 10, cartridge nominal length 10 in. (25 cm), filter diam. 5.7 in. (14.5 cm)

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
23151806

Materiales

mixed cellulose esters (MCE) membrane
polyester support
polypropylene filter
polypropylene housing
silicone seal

Nivel de calidad

cumplimiento norm.

FDA 21CFR177-182 (all component materials)

esterilidad

non-sterile

Compatibilidad de esterilización

autoclavable compatible

Línea del producto

Opticap® XL 10

Características

hydrophilic

fabricante / nombre comercial

Opticap®

Parámetros

1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

técnicas

prefiltration: suitable

longitud nominal del cartucho

10 in. (25 cm)

device L

33.5 cm (13.2 in.)

device size

10 in.

diám. del filtro

5.7 in. (14.5 cm)

filter filtration area

0.8 m2

diám. conexión a entrada

9/16 in.

inlet to outlet width

33.5 cm (13.2 in.)

diám. conexión a salida

9/16 in.

impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)

matriz

Milligard® LPB

tamaño de poro

0.5 μm nominal pore size
0.5 μm pore size

Adaptador

(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Device Configuration: Capsule

Características y beneficios

Single Layer

Envase

Double Easy-Open bag

Especificaciones

Filter Grade: Low Protein Binding Milligard® Media

Nota de preparación

Sterilization Method:
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Nota de análisis

Gravimetric Extractables: ≤ 105 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 5 L

Otras notas

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of Opticap® XL Capsules and Opticap® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Información legal

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Herramienta de selección de productos.


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico