KVEPG015FF1
Millipore Express® SHR, Opticap® XL Capsule
Opticap® XL 150, cartridge nominal length 3.8 in. (9.7 cm), filter diam. 5.6 cm (2.2 in.)
About This Item
Materiales
polyethylene support
polypropylene device
polypropylene housing
polypropylene vent cap
silicone seal
Nivel de calidad
cumplimiento norm.
meets FDA 21 CFR 177-182 (all component materials)
esterilidad
non-sterile
Compatibilidad de esterilización
gamma compatible
Línea del producto
Opticap® XL 150
Características
hydrophilic
fabricante / nombre comercial
Millipore Express®
Parámetros
≤1.4 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
técnicas
sterile filtration: suitable
Anchura
2.2 in.
longitud nominal del cartucho
3.8 in. (9.7 cm)
device L
9.7 cm (3.8 in.)
diám. del filtro
5.6 cm (2.2 in.)
filter filtration area
250 cm2
impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matriz
Millipore Express® SHR
tamaño de poro
0.1 μm pore size
punto de burbuja
≥4000 mbar (58 psig), air with water
Adaptador
(19 mm (¾ in.) Sanitary Flange Inlet and Outlet)
¿Está buscando productos similares? Visita Guía de comparación de productos
Descripción general
Envase
Nota de preparación
Gamma Compatible to 45 kGy. May be autoclaved for 3 cycles of 60 min at 123 °C; not in-line steam sterilizable
Nota de análisis
Otras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Información legal
¿No encuentra el producto adecuado?
Pruebe nuestro Herramienta de selección de productos.
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico