Saltar al contenido
Merck
Todas las fotos(1)

Documentos

1.14848

Supelco

Phosphate Test, photometric

photometric, 0.0025-5.00 mg/L (PO4-P), 0.0077-15.3 mg/L (PO43-), 0.0057-11.46 mg/L (P2O5), Spectroquant®

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41116116
NACRES:
NA.24

product name

Phosphate Test, photometric, 0.0025-5.00 mg/L (PO4-P), 0.0077-15.3 mg/L (PO43-), 0.0057-11.46 mg/L (P2O5), Spectroquant®

Línea del producto

Spectroquant®

Nivel de calidad

uso

sufficient for 220 tests (depending on package size)
sufficient for 420 tests

analitos específicos

phosphate

intervalo de medida

0.0025-5.00 mg/L (PO4-P)
0.0057-11.46 mg/L (P2O5)
0.0077-15.3 mg/L (PO43-)

técnicas

photometry: suitable

compatibilidad

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600

método de detección

photometric (Phosphomolybdenum blue)

temp. de almacenamiento

15-25°C

Descripción general

(o-phosphate) Method: photometric, PMB 0.0025 - 5.00 mg/l PO₄-P 0.0077 - 15.3 mg/l PO₄ 0.0057 - 11.46 mg/l P₂O₅ Spectroquant®
The method is analogous to EPA 365.2+3, APHA 4500-P E, and DIN EN ISO 6878.
The Spectroquant®Phosphate Reagent Test allows the accurate quantification of phosphate. Elevated levels of phosphate might lead to eutrophication of water bodies, which is a risk to the environment.
Therefore, the concentration of phosphate in drinking water and wastewater is regulated in many countries. Further applications are the determination of phosphate in foods & beverages (e.g. beer) and in environmental and agricultural samples (e.g. soil).
The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet.
All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Aplicación



  • Effects of Two Remineralizing Agents in Combination with Er:YAG and CO(2) Laser Irradiation on Microhardness of Demineralized Enamel: This study highlights the use of phosphate tests in dental research, specifically in measuring the efficacy of remineralizing agents combined with laser treatment to enhance enamel hardness, which is crucial for dental health and preventive care (Mapar M et al., 2024).


  • Zinc and Silicon Nano-Fertilizers Influence Ionomic and Metabolite Profiles in Maize to Overcome Salt Stress: This research utilizes phosphate tests in the study of plant physiology, specifically to gauge the efficacy of nano-fertilizers in enhancing phosphate uptake under salt stress conditions, providing insights into sustainable agricultural practices (Shoukat A et al., 2024).


  • Investigation of Mechanical Properties of Polymer-Infiltrated Tetrapodal Zinc Oxide in Different Variants: Applies phosphate testing in the field of materials science to assess the interaction of phosphate with novel composite materials, thereby informing the development of more durable and efficient materials for various industrial applications (Scherer F et al., 2024).


Información legal

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

Corrosion

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Código de clase de almacenamiento

8B - Non-combustible, corrosive hazardous materials

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Spectroquant® photometric test accurately quantifies low concentrations of PO4-P in natural waters.

Protocolos

Photometric determination of phosphate ions in water with ammonium molybdate using Spectroquant® test kits and a UV/VIS spectrophotometer.

Photometric determination of phosphate ions in fertilizer samples using phosphorus molybdenum blue and Spectroquant® test kits.

Photometric determination of total phosphorus in plant material samples by phosphorus molybdenum blue method using Spectroquant® test kits.

Photometric determination of phosphate ions in manure samples using phosphorus molybdenum blue and Spectroquant® test kits.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico