UFC9050
Amicon® Ultra Centrifugal Filter, 50 kDa MWCO
sample volume 15 mL, regenerated cellulose membrane, MWCO 50 kDa
Synonym(s):
15 mL sample volume, 50 kDa MWCO, Centrifugal concentrator
About This Item
Recommended Products
material
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
Quality Level
sterility
non-sterile
product line
Amicon®
manufacturer/tradename
Amicon® Ultra
parameter
15 mL sample volume
technique(s)
protein extraction: suitable
protein purification: suitable
L
12.1 cm (4.807 in.)
diam.
2.97 cm
filtration area
7.6 cm2
volume
15 mL
pore size
50 kDa MWCO
shipped in
ambient
General description
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon®Ultra 15 mL filters deliver the highest recovery with short spin times.
Application
- Ultrafiltration with 50,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
Features and Benefits
- Ultracel® regenerated cellulose membrane with 50 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipettor sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
Physical form
Legal Information
Not finding the right product?
Try our Product Selector Tool.
Storage Class Code
10-13 - German Storage Class 10 to 13
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Filtration methods and membrane filter selection in nanoparticle purification and production.
Explore ultrafiltration membrane principles and benefits for protein sample preparation, including solvent exchange and sample concentration.
Related Content
Concentrate protein, don’t lose it. Recover protein reliably when you concentrate with Amicon® Ultra filters.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service