H2625

Sigma-Aldrich

Hemoglobin from bovine blood

suitable for protease substrate, substrate powder

Synonym(s):

Bovine hemoglobin, Hb, Methemoglobin

Sign Into View Organizational & Contract Pricing


About This Item

CAS Number:
MDL number:
UNSPSC Code:
12352202
eCl@ss:
42030116
NACRES:
NA.61

biological source

bovine blood

form

substrate powder

mol wt

Mr ~64500

technique(s)

activity assay: suitable

solubility

H2O: soluble 20 mg/mL

suitability

suitable for protease substrate

UniProt accession no.

storage temp.

2-8°C

Looking for similar products? Visit Product Comparison Guide

General description

Hemoglobin is the major component of red blood cells and is responsible for their red color. Its normal concentration in erythrocytes is 34%. Hemoglobin is a globular protein with α and β chains with every 141 and 146 amino acids respectively. It exists as a tetramer with each monomer having heterocyclic porphyrin ring with iron constituting the heme.
Hemoglobin is the major component of red blood cells, and is responsible for their red color. Its normal concentration in erythrocytes is 34%. Hemoglobin is the most important respiratory protein of vertebrates by virtue of its ability to transport oxygen from the lungs to body tissues, and to facilitate the return transport of carbon dioxide.

Application

Hemoglobin from bovine blood has been used as a substrate in cathepsin D activity assay. It has also been used to measure the activity of acid proteases (pepsin-like) in the stomach extract.
The solubility of α-elastin has been applied to construction of elastin-mimetic biomaterials.

Biochem/physiol Actions

Bovine hemoglobin is used in the production of hemoglobin-vesicles (HbV). It has high thermal stability and high oxygen affinity when compared to human hemoglobin. Bovine hemoglobin interacts with synthetic and azo dyes. Polymerized forms of bovine hemoglobin are used to treat autoimmune hemolytic anemia.
Oxygen transporter. The Fe2+/Fe3+ balance is a physiological indicator of blood oxygenation; deoxygenated hemoglobin accessorizes a feedback loop by reducing nitrite to NO, a vasodilator which enhances blood flow to oxygen-deprived tissues.

Caution

Since native hemoglobin is readily oxidized in air, these preparations may be predominantly methemoglobin.

Preparation Note

Prepared from washed, lysed and dialyzed erythrocytes.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Luke J Norbury et al.
Biochimie, 93(3), 604-611 (2010-12-21)
Cathepsin proteases are promising vaccine or drug targets for prophylaxis or therapy against Fasciola parasites which express cathepsin L and B proteases during their development. These proteases are believed to be involved in important functions for the parasite, including excystment
A study of the interaction of bovine hemoglobin with synthetic dyes using spectroscopic techniques and molecular docking
Bansal S, et al.
Frontiers in Chemistry, 4(4), 50-50 (2017)
High pressure effects on the activities of cathepsins B and D of mackerel and horse mackerel muscle
Fidalgo L, et al.
Czech Journal of Food Sciences, 32(2), 188-193 (2016)
Characteristics of bovine hemoglobin as a potential source of hemoglobin-vesicles for an artificial oxygen carrier
Sakai H, et al.
Journal of Biochemistry, 131(4), 611-617 (2002)
Xianbo Lu et al.
Biosensors & bioelectronics, 23(8), 1236-1243 (2007-12-18)
Carbon nanofibers (CNFs), with typical diameters of approximately 80 nm and lengths of the order of micrometers, are extremely attractive in bioanalytical area as they can combine properties of high surface area, non-toxicity, acceptable biocompatibility, ease of fabrication, chemical and

Protocols

This procedure may be used for determination of Pepsin activity using hemoglobin as the substrate. It is a spectrophotometric stop rate determination.

Proteinase K activity measured via spectrophotometry using hemoglobin substrate, crucial for enzyme characterization.

Proteinase K activity measured via spectrophotometry using hemoglobin substrate, crucial for enzyme characterization.

Proteinase K activity measured via spectrophotometry using hemoglobin substrate, crucial for enzyme characterization.

See All

Chromatograms

application for HPLC

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service