GE17-0727-20
SOURCE™ 15RPC
Cytiva 17-0727-20, pack of 10 mL
About This Item
Productos recomendados
ligand
matrix surface
feature
autoclavable 20 min at 121°C
packaging
pack of 10 mL
manufacturer/tradename
Cytiva 17-0727-20
matrix
polystyrene/divinylbenzene
avg. part. size
15 μm (monosized)
cleaning in place
1-14
working range
1-12
capacity
~10 mg binding capacity
suitability
suitable for bioprocess medium
General description
Application
High quality assurance standards in combination with the patented production method, particle structure is consistent both bead-to-bead and batch-to-batch.
A controlled pore size distribution and large specific surface area offer excellent capacity for a wide range of molecules, from small peptides and oligonucleotides up to large Proteins. With full pH range stability, SOURCE™ 15RPC is a strong alternative to silica-based RPC matrices.
SOURCE™ 15RPC is available in a range of different bulk pack sizes for easy scale-up and process development. As member of the BioProcess media range, SOURCE™ 15RPC meets industrial demands with security of supply and comprehensive technical and regulatory support.
Features and Benefits
- Mono-sized 15 μm rigid beads gives Low back pressures and high flow rates allowing for high productivity.
- Designed for high resolution reversed phase chromatography of Proteins, peptides and oligonucleotides.
- High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
- BioProcess medium supported for industrial applications.
Storage and Stability
Analysis Note
Legal Information
signalword
Warning
hcodes
Storage Class
3 - Flammable liquids
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Artículos
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
Protocolos
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico