Saltar al contenido
Merck

Saltar a

IPFL00010

Immobilon® -FL PVDF Membrane

1 roll, 27 cm x 3.75 m, 0.45 µm pore size, transfer membrane with low background fluorescence

Immobilon®-FL PVDF Membrane

Sinónimos:

Western blotting membrane, blotting membrane, transfer membrane

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
A ustedes/SKUDisponibilidadPrecio

Acerca de este artículo

UNSPSC Code:
41105339
eCl@ss:
32031602
NACRES:
NB.22
Material:
PVDF membrane, plain filter, white filter
Detection method:
chemiluminescent, colorimetric, fluorometric
Pore size:
0.45 μm pore size
Compatibility:
for use with All fluorescence dyes, for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Nombre del producto

Membrana de PVDF Immobilon®-FL, 1 roll, 27 cm x 3.75 m, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane with low background fluorescence for Western blotting. Compatible with visible and infrared fluorescent probes.

Quality Segment

material

PVDF membrane, plain filter, white filter

feature

hydrophobic

manufacturer/tradename

Immobilon®

technique(s)

dot blot: suitable, western blot: suitable

filter L × W

27 cm × 3.75 m

pore size

0.45 μm pore size

capacity

155 μg/cm2 adsorption capacity (insulin), 205 μg/cm2 adsorption capacity (BSA), 300 μg/cm2 adsorption capacity (goat IgG)

compatibility

for use with All fluorescence dyes, for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby

detection method

chemiluminescent, colorimetric, fluorometric

shipped in

ambient

General description

La membrana de transferencia Immobilon®-FL es una membrana microporosa de fluoruro de polivinilideno (PVDF) con un tamaño nominal de poro de 0,45 μm. Está diseñada para adsorber las proteínas transferidas desde una variedad de matrices de gel. La membrana de transferencia Immobilon®-FL es hidrófoba y ofrece una estructura de poro uniformemente controlada con una gran capacidad de adsorción para biomoléculas. La membrana ofrece una transferencia óptima para proteínas con pesos moleculares superiores a 20 000. La membrana Immobilon®-FL muestra una autofluorescencia muy baja en una amplia gama de longitudes de onda de excitación/emisión. Esta propiedad la hace ideal para aplicaciones de transferencia que implican inmunodetección por fluorescencia. La membrana Immobilon®-FL también puede utilizarse para la detección quimioluminiscente o cromógena convencional.

Application

La membrana de PVDF Immobilon-FL se ha utilizado en la inmunoelectrotransferencia.[1][2]

Features and Benefits

Membrana Immobilon-FL:
  • La primera membrana de transferencia optimizada para aplicaciones de fluorescencia; un fondo extremadamente bajo mejora la sensibilidad de todos los protocolos de detección de fluorescencia
  • Compatible con todas las sondas fluorescentes utilizadas habitualmente en una amplia gama de longitudes de onda de excitación/emisión
  • Mejor para detecciones de multiplexado y quimiofluorescencia
  • Compatible con los bloqueantes y amortiguadores convencionales

Legal Information

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
IPFL20200IPFL10100IPFL00005
material

PVDF membrane, white filter, plain filter

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

detection method

chemiluminescent, fluorometric, colorimetric

detection method

chemiluminescent, colorimetric, fluorometric

detection method

chemiluminescent, colorimetric, fluorometric

detection method

chemiluminescent, colorimetric, fluorometric

compatibility

for use with All fluorescence dyes, for use with CPTS, for use with Ponceau-S red, for use with Amido black, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby, for use with Coomassie brilliant blue

compatibility

for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red

compatibility

for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red

compatibility

for use with All fluorescence dyes, for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®


Still not finding the right product?

Explore all of our products under Membrana de PVDF Immobilon®-FL


Clase de almacenamiento

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable



Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Questions

1–3 of 3 Questions  
  1. What is the thickness of this product?

    1 answer
    1. The thickness range of IPFL00010 is 110-145 microns.

      Helpful?

  2. Is 0.22 µm PVDF membrane available for fluorescent detection in Western blotting?

    1 answer
    1. Immobilon PSQ, with a pore size of 0.2 µm, is suitable for various detection methods including fluorescent, radioactive, chromogenic, and chemifluorescent detection. But when using Immobilon PSQ in Western Blotting, it is important to consider that there may be increased background noise, which might require more stringent wash steps to ensure accurate results.

      Helpful?

  3. Is it possible to use Immobilon FL instead of Immobilon P for western blots?

    1 answer
    1. Yes, Immobilon FL can be used as an alternative to Immobilon P for western blots.

      Helpful?

Reviews

Active Filters

  1. Detroit, MI
    • Review 1
    • Votes 2
    5 out of 5 stars.

    Great for western blots

    I have been using this product for close to two and half years now. It is a highly reliable PVDF roll for western blotting. I use it to transfer a wide variety of proteins and use HRP conjugated secondary antibodies for imaging bands. The results have always been sharp, reliable and most importantly, reproducible. I shall buy again when we run out.

    Helpful?