Accéder au contenu
Merck

TRUE9

TrueGel3D Hydrogel Kits

SLO-PVA, PEG non cell-degradable crosslinker

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue

A propos de cet article

NACRES:
NA.71
UNSPSC Code:
12352207
Storage temp.:
−70°C
Shipped in:
dry ice
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


shipped in

dry ice

storage temp.

−70°C

General description

The gel is formed by stable thioether bonds between thiol groups on PEG non cell-degradable crosslinker and thio-reactive groups on SLO-PVA. The polymer, SLO-PVA is functionalized with thiol-reactive groups which react with crosslinker at slower rate than maleimides in FAST-PVA. SLO-PVA does not have sites for cell attachment, but it can be customized to conjugate RGD peptide using TrueGel3D RGD peptide (TRUERGD-1EA) prior to the crosslinking step.

Application

TRUE9-1KT is used to generate hydrogels of different stiffness (0.15 to 5 KPa shear modulus) to mimic in-vivo conditions and to investigate the effect of matrix stiffness on cell physiology and behavior.SLO-PVA based gels are used to grow cells that do not need attachment to hydrogel for survival but rather use their secreted extracellular matrix. The SLO-PVA based hydrogels are preferred over dextran-based gels for long-term culture of cells producing carbohydrate degrading enzymes. TrueGel3DTM Hydrogel Kits has been used in the generation of 3D gel based tumor models.

Features and Benefits

  • Slow gelling (takes 6 minutes to 25 minutes, depends on gel stiffness)
  • Flexibility in modulating gel stiffness
  • Does not allow cell migration
  • Does not allow cell recovery and post-culture analyses
  • Cell inert hydrogel (if not customized with RGD peptide)

Other Notes

TRUE9-1KT contains SLO-PVA solution in phosphate buffer and lyophilized PEG non cell-degradable crosslinker with reconstitution buffer and water.

Disclaimer

Avoid prolong exposure of PEG non cell-degradable crosslinker to air and store SLO-PVA in small portions to avoid frequent freeze-thaw cycles.


Still not finding the right product?

Explore all of our products under TrueGel3D Hydrogel Kits


pictograms

Corrosion

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

wgk

WGK 3

Classe de stockage

10 - Combustible liquids



Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents