Accéder au contenu
Merck

Passer à

I0503

Isopentenyl pyrophosphate triammonium salt solution

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3)), ≥95% (TLC)

Synonyme(s) :

IPP

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue
Taille/RéférenceDisponibilitéPrix

A propos de cet article

Formule empirique (notation de Hill) :
C5H12O7P2 · 3NH3
Numéro CAS:
Poids moléculaire :
297.18
UNSPSC Code:
12352212
PubChem Substance ID:
NACRES:
NA.25
Assay:
≥95% (TLC)
Le tarif et la disponibilité ne sont pas disponibles actuellement.
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


Quality Segment

assay

≥95% (TLC)

packaging

vial of 200 μg

concentration

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3))

storage temp.

−20°C

SMILES string

N.N.N.CC(=C)CCOP(O)(=O)OP(O)(O)=O

InChI

1S/C5H12O7P2.3H3N/c1-5(2)3-4-11-14(9,10)12-13(6,7)8;;;/h1,3-4H2,2H3,(H,9,10)(H2,6,7,8);3*1H3

InChI key

JREYOWJEWZVAOR-UHFFFAOYSA-N

Application

Intermediate in terpene biosynthesis.

Disclaimer

Supply conditions do not apply to the regions and states of Brazil: North, Northeast, Mato Grosso do Sul, Mato Grosso, and Rio Grande do Sul.

Comparer avec des articles similaires

Voir la comparaison complète

Montrer les différences

1 of 1

Cet article
G6772G6025I0879
description

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3)), ≥95% (TLC)

description

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3)), ≥95% (TLC)

description

solution, ≥95% (TLC), ~1 mg/mL in methanol: NH4OH (7:3)

description

≥95%

assay

≥95% (TLC)

assay

≥95% (TLC)

assay

≥95% (TLC)

assay

≥95%

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

packaging

vial of 200 μg

packaging

vial of 200 μg

packaging

vial of 200 μg

packaging

-

concentration

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3))

concentration

1 mg/mL in methanol (:aqueous 10 mM NH4OH (7:3))

concentration

~1 mg/mL in methanol: NH4OH (7:3)

concentration

-


signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes,Central nervous system

Classe de stockage

3 - Flammable liquids

wgk

WGK 2

flash_point_f

69.8 °F - closed cup

flash_point_c

21 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter



Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents



Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. I would like to inquire about the differences between the products I0503 Isopentenyl pyrophosphate triammonium salt solution and 00297 ISOPENTENYL PYROPHOSPHATE TRILITHIUM SAL, as well as which product is more suitable for immune cell stimulation culture.

    1 answer
    1. The primary difference between the two products is the salt form. The I0503 is a triammonium salt and 00297 is a trilithium salt. These salts will ionize in solution. The secondary difference is that the I0503 is in methanol. As methanol is cytotoxic, it would not be suitable for use with cell or animal models. In addition, the 00297 has not been tested for in vitro use.
      To discuss the difference in properties and potential applications further, please navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquiries" under the Products Section with all the required information so that a member of the Technical Service team can reach out to assist further. Thank you.

      Helpful?

Reviews

No rating value

Active Filters