Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

NIST8671

Anticorps monoclonal IgG1k humanisé NISTmAb

NIST® SRM® 8671

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41116107
Nomenclature NACRES :
NA.41
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Type de produit anticorps

primary antibodies

Qualité

certified reference material

Forme

liquid

Fabricant/nom de marque

NIST®

Technique(s)

UV/Vis spectroscopy: suitable
liquid chromatography (LC): suitable
mass spectrometry (MS): suitable

Format

matrix material

Description générale

L'anticorps monoclonal IgG1k humanisé NISTmAb est un anticorps recombinant exprimé dans une culture de cellules murines en suspension. C′est un homodimère doté de deux chaînes légères identiques et de deux chaînes lourdes identiques reliées par des ponts disulfure inter-chaînes et intra-chaine, d′un poids moléculaire de 150 kDa. Cette protéine présente des modifications post-traductionnelles peu abondantes, notamment du type glycation, déamidation et oxydation de la méthionine. Cet anticorps monoclonal humanisé comporte aussi une pyroglutamination N-terminale, une coupure des résidus lysine C-terminaux et une glycosylation des chaînes lourdes.

Une unité de matériau de référence 8671 se compose d'un cryotube en polypropylène à filetage interne contenant 800 µl de 10 mg/ml d'anticorps monoclonal IgG1κ NIST (NISTmAb) dans 12,5 mmol/l de L-histidine et 12,5 mmol/l de chlorhydrate de L-histidine (pH 6,0).

SRM 8671_Cert

SRM 8671_SDS

Application

L'anticorps monoclonal IgG1k humanisé NISTmAb a servi d'étalon pour tester un algorithme de séquençage de novo en spectrométrie de masse ascendante.[1]Ce matériau de référence permet avant tout d'évaluer les performances des méthodes de détermination des attributs physicochimiques et biophysiques des anticorps monoclonaux. C'est également une molécule d'essai représentative pour la mise au point de nouvelles technologies de caractérisation des protéines thérapeutiques. Parmi ses autres utilisations possibles, citons :
  • les tests de conformité des systèmes
  • la détermination des performances ou de la variabilité des procédés ou des instruments
  • la comparaison de méthodes d'analyse
  • la qualification des procédés

Remarque sur l'analyse

Le produit NIST8671 est destiné aux activités de recherche. Il n′est pas destiné à la consommation humaine ou animale, aux essais cliniques ou aux applications thérapeutiques.

Autres remarques

  • Le matériau de référence 8671 est uniquement destiné à la recherche.
  • Le certificat NIST contient des détails sur la péremption, le stockage, la sécurité, l'utilisation et la source. 
  • La FDS contient des informations sur les biomatériaux, la mise au rebut et le transport.

Informations légales

NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Ioannis Karageorgos et al.
Biologicals : journal of the International Association of Biological Standardization, 50, 27-34 (2017-10-03)
Monoclonal antibody pharmaceuticals are the fastest-growing class of therapeutics, with a wide range of clinical applications. To assure their safety, these protein drugs must demonstrate highly consistent purity and stability. Key to these objectives is higher order structure measurements validated
Automated Antibody De Novo Sequencing and Its Utility in Biopharmaceutical Discovery.
Sen K I, et al.
Journal of the American Society For Mass Spectrometry, 28(5), 803-810 (2017)

Articles

An optimized peptide mapping protocol using NISTmAb as a model monoclonal antibody, shorter incubation times, and improved digestion buffer to demonstrate minimal artificial asparagine deamidation and methionine oxidation.

An optimized peptide mapping protocol using NISTmAb as a model monoclonal antibody, shorter incubation times, and improved digestion buffer to demonstrate minimal artificial asparagine deamidation and methionine oxidation.

An optimized peptide mapping protocol using NISTmAb as a model monoclonal antibody, shorter incubation times, and improved digestion buffer to demonstrate minimal artificial asparagine deamidation and methionine oxidation.

An optimized peptide mapping protocol using NISTmAb as a model monoclonal antibody, shorter incubation times, and improved digestion buffer to demonstrate minimal artificial asparagine deamidation and methionine oxidation.

Afficher tout

Questions

1–3 of 3 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. How many mg are in 1 unit of NIST8671 - NISTmAb, Humanized IgG1k Monoclonal Antibody?

    1 answer
    1. As mentioned in the 'DESCRIPTION' section, one unit or vial of RM 8671 contains 800 µL of 10 mg/mL NIST IgG1k monoclonal antibody (NISTmAb) in 12.5 mmol/L L-histidine, 12.5 mmol/L L-histidine HCl (pH 6.0).

      Helpful?

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique