Accéder au contenu
Merck
Toutes les photos(3)

Principaux documents

F9252

Sigma-Aldrich

Réactif phénolique de Folin-Ciocalteu

Folin & Ciocalteu’s phenol reagent
1 of 2 reviewers received a sample product or took part in a promotion

suitable for determination of total protein by Lowry method, 1.9-2.1 N

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro MDL:
Code UNSPSC :
12171500
Nomenclature NACRES :
NA.47
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Forme

liquid

Niveau de qualité

Concentration

1.9-2.1 N

Couleur

clear yellow
faint yellow to very dark yellow, and Faint Green-Yellow to Very Dark Green-Yellow

pH

<0.5 (20 °C)

Densité

1.240 g/cm3 at 20 °C

Adéquation

suitable for determination of total protein by Lowry method

Application(s)

diagnostic assay manufacturing
hematology
histology

Température de stockage

room temp

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Le réactif phénolique de Folin-Ciocalteu est principalement utilisé dans la méthode de dosage des protéines selon Lowry.[1][2] Il a également été utilisé pour la quantification des composés phénoliques totaux.[3] Dans cette méthode, l′extrait de protéine est prétraité au cuivre(II) dans un réactif de biuret modifié (solution de cuivre alcaline
stabilisée au tartrate double de potassium et de sodium). L′ajout du réactif phénolique génère des chromogènes qui augmentent l′absorbance entre 550 et 750 nm. Typiquement, le pic d′absorbance (750 nm) ou son épaule (660 nm) sont utilisés pour déterminer la concentration des protéines entre 1-100 mg/ml, tandis que l′absorbance à 550 nm est utilisée pour déterminer les concentrations plus élevées.
En l′absence de cuivre, l′intensité de la coloration est déterminée principalement par le contenu en tyrosine et en tryptophane des protéines, et dans une moindre mesure en cystéine et en histidine. Le cuivre(II) n′a aucun effet sur la formation d′une coloration par la tyrosine, le tryptophane ou l′histidine, mais réduit la formation de coloration par la cystéine.[1][4][5][6][7]
De nombreuses modifications de la procédure initiale du dosage ont été publiées[4], dont des méthodes pour accélérer le développement de la coloration[6][8], pour déterminer la teneur en protéines insolubles[1][9] et pour automatiser la procédure.[10] Plusieurs substances comme de nombreux tampons, agents chélateurs, détergents et composés organiques cycliques peuvent interférer avec le dosage des protéines selon Lowry.[4]
Le réactif phénolique de Folin-Ciocalteu peut également être utilisé comme réactif en aérosol dans les procédures chromatographiques.

Application

Le réactif phénolique de Folin-Ciocalteu a été utilisé pour estimer la teneur en composés phénoliques totaux dans les échantillons.[11][12][13]

Autres remarques

Le réactif phénolique de Folin-Ciocalteu ne contient pas de phénol, mais il réagit avec les phénols et les substances réductrices non phénoliques pour former des chromogènes qui peuvent être détectés par méthodes spectrophotométriques.

Liaison

Ce produit est également disponible comme constituant d′un kit.

Pictogrammes

Corrosion

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1

Code de la classe de stockage

8B - Non-combustible corrosive hazardous materials

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Lowry's method of protein estimation: some more insights.
S Sengupta et al.
The Journal of pharmacy and pharmacology, 45(1), 80-80 (1993-01-01)
Nutritional evaluation of some subtropical red and green seaweeds Part II. In vitro protein digestibility and amino acid profiles of protein concentrates.
Wong KH and Cheung PCK
Food Chemistry, 72, 11-17 (2001)
Han-Shin Kim et al.
Scientific reports, 6, 25318-25318 (2016-05-05)
Biofilm formation on biotic or abiotic surfaces has unwanted consequences in medical, clinical, and industrial settings. Treatments with antibiotics or biocides are often ineffective in eradicating biofilms. Promising alternatives to conventional agents are biofilm-inhibiting compounds regulating biofilm development without toxicity
Picheswara Rao Polu et al.
BMC complementary and alternative medicine, 17(1), 457-457 (2017-09-13)
Tinospora cordifolia (Guduchi or Amrita) is an important drug of Ayurvedic System of Medicine and found mention in various classical texts for the treatment of diseases such as jaundice, fever, diabetes, cancer and skin disease etc. In view of its
H J Fryer et al.
Analytical biochemistry, 153(2), 262-266 (1986-03-01)
The method of protein determination reported by Lowry et al. (1951, J. Biol. Chem. 193, 265-275) has been adapted for use with 96-well microtiter plates and an automatic microplate spectrophotometer. The spectrophotometer has been interfaced with a computer which plots

Protocoles

To standardize a procedure for the determination of protein by modified Lowry.

To standardize a procedure for the determination of protein by modified Lowry.

To standardize a procedure for the determination of protein by modified Lowry.

To standardize a procedure for the determination of protein by modified Lowry.

Afficher tout

Contenu apparenté

Products for traditional and alternative protein quantitation techniques available, including BCA, Bradford, Lowry, and more.

Products for traditional and alternative protein quantitation techniques available, including BCA, Bradford, Lowry, and more.

Questions

1–8 of 8 Questions  
  1. We have received Folin & Ciocalteus phenol reagent F9252-100mL, PCode: 102600991, Source: BCCJ8511 from Sigma(Merck). Is the reagent suitable for Phenol content determination? Is the reagent prepare by following BP/EP?

    1 answer
    1. This product is not tested according the BP or JP guidelines. This reagent is not recommended for the determination of phenols. HIstorically, the performance of this product in the determination of phenolic compounds, typically run in wineries, has proven to be unpredictable. It is recommended for use primarily in Lowry protein determination.

      Helpful?

  2. 貴社が販売しているFolin & Ciocalteuフェノール試薬は毒物や劇物に該当しないとの認識でよろしいでしょうか。

    1 answer
    1. The information requested can be found on the Product Safety Data Sheet. The document can be downloaded from the top right-hand side of the Product Detail Page under ‘Documents’. A Safety Data Sheet can also be downloaded from the following link: https://www.sigmaaldrich.com/search

      Please refer to Section 2 for the various hazards associated with this material. The bottle label will show a "Danger" pictogram and is considered a dangerous product.

      Helpful?

  3. How do I differentiate the spectrophotometric result obtained from this reagent is either because of reaction with phenols or non-phenolic reducing substances? Thanks.

    1 answer
    1. The type and amount of non-phenolic compounds present is a given sample will determine the impact on the total phenol values. The use of a standard curve is critical. Factors such as pH adjustment can minimize the effects. Reducing compounds may be identified and quantified separately or removed from the sample by various means. See the links below to review several publications that may be useful.

      https://waterhouse.ucdavis.edu/folin-ciocalteau-micro-method-total-phenol-wine
      https://www.mdpi.com/2076-3417/13/4/2135
      https://pubs.rsc.org/en/content/articlelanding/2013/ay/c3ay41125g
      https://link.springer.com/chapter/10.1007/978-3-319-45776-5_25

      Additional assistance can be provided by our Technical Service team who can assist you further. We kindly ask you to navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquires" under the Products Section with all the required information so that a member of our team can reach out to you to assist further. Thank you.

      Helpful?

  4. What should Product F9252, Folin & Ciocalteu's phenol reagent, look like?

    1 answer
    1. The Folin & Ciocalteu's phenol reagent should be a clear yellow solution.  If the solution turns green, it may not be suitable and it should not be used.

      Helpful?

  5. Does Product F9252, Folin & Ciocalteu's phenol reagent, contain phenol?

    1 answer
    1. The Folin & Ciocalteu's phenol reagent does not contain phenol but reacts with phenol and non-phenolic reducing substances to form chromogens that can be detected spectrophotometrically.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  7. Can Product F9252, Folin & Ciocalteu's phenol reagent, be used to detect any protein?

    1 answer
    1. If the protein has an abnormally low tyrosine content, this method would not be suitable.

      Helpful?

  8. What concentrations of proteins does Product F9252, Folin & Ciocalteu's phenol reagent, detect?

    1 answer
    1. Generally, Folin & Ciocalteu's phenol reagent is used to determine protein concentrations between 1 to 100 μg/mL. However, the reagent exhibits a linear response to protein concentration up to 1000 μg/mL when used according to the instructions for kit Product No. TP0200.

      Helpful?

Reviews

1 of 2 reviewers received a sample product or took part in a promotion

Active Filters

  1. Madri, Spain.
    • Review 1
    • Votes 3
    5 out of 5 stars.

    Reliable reagent

    This reagent is the most suitable for this technique. More reliable results are obtained.

    Helpful?

  2. 1 Ratings-Only Review

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique