We have not performed extractables/leachables studies for our Stericup® filters.
SEGPU0538
Stericup® E-GP Funnel-less Sterile Vacuum Filtration System
pore size 0.22 μm, polyethersulfone membrane, capacity 500 mL, 38 mm (1 1/2 in.) thread, pack of 12 ea
Synonyme(s) :
Système de filtration stérilisante sous vide sans entonnoir Stericup® E-GP, Unité de filtration respectueuse de l'environnement Stericup® E-GP
About This Item
Produits recommandés
Matériaux
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Niveau de qualité
Stérilité
sterile; irradiated
Gamme de produits
Stericup®
Caractéristiques
hydrophilic
Conditionnement
pack of 12 ea
Caractéristiques du produit alternatif plus écologique
Waste Prevention
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
Paramètres
max. temp. at 45 °C
Description
2.4 mL (hold-up volume)
Technique(s)
sterile filtration: suitable
Hauteur
193 mm
Capacité
500 mL
Diamètre
9.3 cm
Capacité du filtre
500 mL
Diam. du filtre
73 mm
Surface de filtration
40 cm2
Matrice
Express PLUS™
Dimension de pores
0.22 μm pore size
Raccords
inlet thread(s)
38 mm (1 1/2 in.) thread
Autre catégorie plus écologique
Conditions d'expédition
ambient
Description générale
Pour de plus amples informations, veuillez consulter la BASE DE DONNÉES ACT
Les dispositifs de filtration stérilisante Stericup® E et Steritop® E sont conçus comme une alternative de filtration stérilisante sous vide plus respectueuse de l'environnement, qui réduit de manière significative l'utilisation de plastiques et d'emballages.
Le modèle Stericup® E est une unité de filtration à col fileté de 38 mm qui utilise une membrane en polyéthersulfone (PES) de 0,22 µm de dimension de pores avec un flacon de réception de 500 ml et un bouchon pour le traitement et le stockage. Le filetage de 38 mm s'adapte directement sur nos flacons pour milieu et la majorité des autres flacons pour milieu standard commercialisés.
Utiliser uniquement des flacons en verre ou en plastique conçus pour des applications sous vide.
Application
- Milieux de culture cellulaire +/- additifs
- Tampons
- Solutions biologiques
Caractéristiques et avantages
- Le se déconnecte du flacon de réception en un quart de tour, ce qui réduit le risque de déversement et facilite la manipulation sur la paillasse ou sous la hotte.
- L'identification en gras du produit sur le col du filtre affiche clairement les caractéristiques de la membrane, notamment la composition et la taille des pores, pour une sélection rapide du produit adapté à l'application.
- Le bouchon à fermeture par clic est muni d'une collerette et est modifié pour assurer une prise en main sûre aussi bien en conditions humides que sèches et une butée tactile confirme la fermeture sécurisée. Ne vous inquiétez pas du risque de déversement ou de contamination du contenu stérilisé.
- Une large zone d'écriture dépolie sur le flacon de réception et la couleur plus claire du bouchon permettent un étiquetage clair pour améliorer la lisibilité et réduire les bavures illisibles.
- Le bouchon à fermeture par clic repose sur le côté pour éviter tout risque de contamination.
- Les flacons de réception sont empilables pour gagner de l'espace de stockage.
Autres remarques
Informations légales
En option
Produit(s) apparenté(s)
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Contenu apparenté
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
-
What leachables are detected during filtration processes using Stericup® filters?
1 answer-
Helpful?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 answer-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
Helpful?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 answer-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
Helpful?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 answer-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 answer-
No, all Stericup® and Steritop® devices are Research Use Only.
Helpful?
-
-
Can Stericup® and Steritop® filters be reused?
1 answer-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
Helpful?
-
-
What is the maximum vacuum pressure for filtration?
1 answer-
700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)
Helpful?
-
-
What Bacterial Endotoxins Test is used?
1 answer-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
Helpful?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 answer-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Helpful?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 answer-
Typically 3 years from sterilization.
Helpful?
-
Active Filters
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique