C-117
Corticosterone solution
1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
1.0 mg/mL in methanol
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
clinical testing
clinical testing
Format
single component solution
Température de stockage
−20°C
Chaîne SMILES
CC12CC(O)C3C(CCC4=CC(=O)CCC34C)C1CCC2C(=O)CO
InChI
1S/C21H30O4/c1-20-8-7-13(23)9-12(20)3-4-14-15-5-6-16(18(25)11-22)21(15,2)10-17(24)19(14)20/h9,14-17,19,22,24H,3-8,10-11H2,1-2H3/t14-,15-,16+,17-,19+,20-,21-/m0/s1
Clé InChI
OMFXVFTZEKFJBZ-HJTSIMOOSA-N
Description générale
Application
- Corticosterone ELISA kit for stress hormone research: Research has demonstrated the efficacy of corticosterone ELISA kits in measuring stress hormone levels, contributing significantly to studies on adrenal gland function and stress-related disorders. This application is vital for in vivo corticosterone analysis, allowing detailed monitoring of hormone fluctuations in response to various stressors (Ornelas et al., 2024).
- High-purity corticosterone for receptor binding assays: Corticosterone solutions are extensively used in receptor binding assays to understand corticosteroid receptor interactions. These studies are crucial for advancing knowledge in endocrinology biochemical studies, particularly in mapping corticosteroid pathways and their effects within the body (Xie et al., 2024).
- Synthetic corticosterone solution for endocrine studies: Synthetic corticosterone is employed in clinical experimental setups to examine the endocrine system′s response under controlled conditions. This usage is particularly evident in studies focusing on the adaptation of the endocrine system to external stress factors and its impact on overall physiological health (Costa et al., 2024).
- Liquid corticosterone for stress response research: Liquid formulations of corticosterone are pivotal in conducting stress response research, providing a consistent and measurable means of administering this hormone to study its acute and chronic effects on animal behavior and physiological responses (Ornelas et al., 2023).
- Corticosterone reagent for glucocorticoid receptor experiments: As a reagent, corticosterone is integral to glucocorticoid receptor experiments, which are essential for understanding glucocorticoid receptor dynamics and their implications in various physiological processes, including immune response and metabolic regulation (Heraudeau et al., 2023).
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organes cibles
Eyes
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Protocoles
The conversion of clinical methods to LC/MS/MS offers advantages; however, is accompanied by a few limitations, notably interference effects from the endogenous sample matrix.
The conversion of clinical methods to LC/MS/MS offers advantages; however, is accompanied by a few limitations, notably interference effects from the endogenous sample matrix.
The conversion of clinical methods to LC/MS/MS offers advantages; however, is accompanied by a few limitations, notably interference effects from the endogenous sample matrix.
The conversion of clinical methods to LC/MS/MS offers advantages; however, is accompanied by a few limitations, notably interference effects from the endogenous sample matrix.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique