30501-M
Ammonium hydroxide solution
puriss. p.a., reag. ISO, reag. Ph. Eur., ≥25% NH3 basis
Synonym(s):
Ammonia aqueous, Ammonia water
About This Item
Recommended Products
Agency
USP/NF
reag. ISO
reag. Ph. Eur.
Quality Level
grade
puriss. p.a.
form
liquid
expl. lim.
27 %
concentration
≥25% NH3
impurities
readily oxidisable substances, complies
≤0.00005% pyridine
≤0.0005% KMnO4 red. matter (as O)
≤1 ppm heavy metals (as Pb)
evapn. residue
≤0.0018%
density
0.892-0.910 g/mL at 20 °C
0.9 g/mL at 25 °C (lit.)
anion traces
carbonate (CO32-): ≤10 ppm
chloride (Cl-): ≤0.5 ppm
phosphate (PO43-): ≤0.5 ppm
silicate (as SiO2): ≤10 ppm
sulfate (SO42-): ≤2 ppm
sulfide (S2-): ≤0.2 ppm
cation traces
Ag: ≤0.02 ppm
Al: ≤0.5 ppm
Au: ≤0.1 ppm
Ba: ≤0.05 ppm
Bi: ≤0.1 ppm
Ca: ≤1 ppm
Cd: ≤0.05 ppm
Co: ≤0.05 ppm
Cr: ≤0.05 ppm
Cu: ≤0.1 ppm
Fe: ≤0.1 ppm
Ga: ≤0.02 ppm
In: ≤0.02 ppm
K: ≤0.5 ppm
Li: ≤0.02 ppm
Mg: ≤0.1 ppm
Mn: ≤0.05 ppm
Mo: ≤0.05 ppm
Na: ≤1 ppm
Ni: ≤0.05 ppm
Pb: ≤0.05 ppm
Pt: ≤0.1 ppm
Sn: ≤0.1 ppm
Sr: ≤0.2 ppm
Ti: ≤0.1 ppm
Tl: ≤0.05 ppm
Zn: ≤0.1 ppm
SMILES string
[NH4+].[OH-]
suitability
complies for appearance of solution
storage temp.
2-8°C
InChI
1S/H3N.H2O/h1H3;1H2
InChI key
VHUUQVKOLVNVRT-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Application
- Ammonium Hydroxide in Material Adsorption: Ammonium hydroxide is used to enhance the adsorption capacity of alginate-based magnetic nanocomposite beads for removing heavy metal ions from water, showcasing its effectiveness in water purification technologies (Russo et al., 2024).
- Capillary Electrophoresis for Nanoplastics: Ammonium hydroxide is utilized in developing methodologies for the separation and detection of nanoplastic particles using capillary electrophoresis, crucial for environmental monitoring and safety assessments (Adelantado et al., 2024).
Packaging
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1B - STOT SE 3
Target Organs
Respiratory system
Storage Class Code
8A - Combustible corrosive hazardous materials
WGK
WGK 2
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Validate urine sample cleanup with HLB SPE for opioid analysis via LC-MS/MS using the Supel™ Swift HLB 96-well plate.
Validate urine sample cleanup with HLB SPE for opioid analysis via LC-MS/MS using the Supel™ Swift HLB 96-well plate.
Validate urine sample cleanup with HLB SPE for opioid analysis via LC-MS/MS using the Supel™ Swift HLB 96-well plate.
Validate urine sample cleanup with HLB SPE for opioid analysis via LC-MS/MS using the Supel™ Swift HLB 96-well plate.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service