Direkt zum Inhalt
Merck
  • Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

Talanta (2014-05-21)
Aníbal Valenzuela, Gaëtane Lespes, Waldo Quiroz, Luis F Aguilar, Manuel A Bravo
ZUSAMMENFASSUNG

A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME StableFlex Methodenentwicklungs-Kit, for use with manual holder
Supelco
SPME-Faseranordnung, Carbowax-Polyethylenglycol (PEG)-Beschichtung, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME StableFlex Methodenentwicklungs-Kit, needle size 23 ga, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPME-Fasersortiment-Kit 4, for use with manual holder, size 24 ga
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga